Rs-232 (Db-25) Receptacle; Table 11: Rs-232 Db25 Receptacle (Female) - Nanoptix SPILL PROOF Service Manual

Table of Contents

Advertisement

RS-232 (DB-25) receptacle

Pin
Signal Name
1
DGND
2
RS232_TXD
3
RS232_RXD
4
RS232_RTS
5
RS232_CTS
6
nc or RS232_CTS
7
DGND
8
nc or 4K7 pull up
9
NC
10
NC
11
NC
12
NC
13
NC
14
NC
15
NC
16
NC
17
NC
18
NC
19
NC
20
RS232_RTS
4k7pu
21
NC
22
NC
23
NC
24
NC
25
INIT
Document # 720003-0000
December 2015
Printer I/O
Ground
Output
Input
Output
Input
Input
Ground
5V Output
No connect
No connect
No connect
No connect
No connect
No connect
No connect
No connect
No connect
No connect
No connect
or
Output
No connect
No connect
No connect
No connect
Input

Table 11: RS-232 DB25 Receptacle (Female)

SPILL PROOF / SPILL PROOF CUTS
Host I/O
Printer Function
Ground
Signal Ground/Aux
Ground
Input
Data transmit
Output
Data receive
Input
Handshaking
Output
Handshaking
Output
Handshaking
Ground
Signal
Ground
n/a
Aux Power (100mA)
No connect
Reserved
No connect
Reserved
No connect
Reserved
No connect
Reserved
No connect
Reserved
No connect
Reserved
No connect
Reserved
No connect
Reserved
No connect
Reserved
No connect
Reserved
No connect
Reserved
Input
Handshaking
No connect
Reserved
No connect
Reserved
No connect
Reserved
No connect
Reserved
Output
System
high)
Service Manual
Ground/Aux
Reset
(active
24