How to reset the Hour Counter
1. Be sure to turn OFF the engine
before beginning the reset proce-
dure. Pull the emergency stop
switch clip out of the emergency
stop switch by pulling the emer-
gency stop switch lanyard.
2. Put the shift lever in "F" (Forward)
or "R" (Reverse).
3. Turn the ignition switch ON. Do
not start the engine. The buzzer will
sound once.
4. Press the emergency stop switch
5 times within 20 seconds.
When using the control panel
without indicators type, within 20
seconds, pull and insert the
emergency stop switch clip, or
remove the clip and pull the
emergency stop switch 5 times.
The buzzer will sound once
indicating the hour counter is reset.