Example
show logging driverlog
e
Syntax
Parameters
Defaults
Command Modes
1572
|
E-Series Debugging and Diagnostics
Figure 65-25. show interfaces tengigabitethernet Command Example
FTOS#show interfaces tengigabitethernet 4/0 link-status
Port Status
Loss of Signal
RX Signal Lock Error
PCS Link State
Link Faults
Remote
Local
Idle Error
Illegal Symbol
Error Symbol
FTOS#
Table 65-3
defines the information displayed in
Table 65-3. Lines in show interfaces tengigabitethernet Command Example
Line
Loss of Signal
Rx Signal Lock Error
PCS Link State
Link Fault Remote.
Link Fault Local.
Link Fault Idle Error
Link Fault Illegal Symbol
Link Fault Error Symbol.
Display the driver log for the RPM CP processor or for the line card CPU in the specified slot.
show logging driverlog [linecard number]
linecard number
(OPTIONAL) Enter the keyword
to display the driver log for the specified line card.
Range: 0 to 13 on a E1200, 0 to 6 on a E600/E600i, and 0 to 5 on an E300
No default values or behavior
EXEC
EXEC Privilege
: FALSE (XFP has power)
: TRUE (Lock detected)
: Down
: None (No Fault)
: Fault (Fault present)
: False (Not received)
: False (Not received)
: False (Not received)
Figure
65-25.
Description
Indicates if the interface has detected the required number of digital bit
transitions (from 1 to 0 and 0 to 1) on the incoming signal. A 10 GE link must
detect a certain number of such transitions for proper synchronization.
Indicates a loss of timing condition. The receive clock must be recovered
from the incoming data stream to allow the receiving physical layer to
synchronize with the incoming electrical pulses.
Display the state of the PCS (Physical Coding sub-layer). The state is either
up or down.
Indicates if the remote device has detected a fault, is inhibiting transmission
of frames, and may be continuously transmitting idle messages.
Indicates if a local fault is detected that may inhibit transmission of frames,
and may be continuously transmitting remote fault signals.
Indicates the detections of a non-idle symbol during an idle period.
Indicates the detections of an illegal symbol, other than an error symbol,
while receiving data frames.
Indicates the detections of an error symbol while receiving data frames.