Download Print this page

Dell Force10 TeraScale E Series Reference Manual page 1547

Ftos command line, ftos 8.4.2.7

Advertisement

reset linecard
e
Reset a specific line card module (power-off and then power-on).
Syntax
reset linecard slot-number
Parameters
slot-number
Defaults
No default values or behavior
Command Modes
EXEC Privilege
Command
Version 6.5.4.0
History
Related
power on/off linecard
Commands
reset sfm
e
Reset a specific SFM module (power-off and then power-on).
Syntax
reset sfm slot-number
Parameters
slot-number
Defaults
No default values or behavior
Command Modes
EXEC Privilege
Command
Version 6.5.4.0
History
Usage
When an error is detected on an SFM module, this command is a manual recovery mechanism. Since
Information
this command can be used with live traffic running, the switch fabric will not go down if the switch
fabric is in an UP state. When there is a full set of SFMs online in the chassis, resetting one SFM will
reduce the total bandwidth supported by the chassis and may affect data flow. A warning message is
issued at the command line and requires user confirmation to proceed
Example
Figure 65-7. reset sfm Command Example with Warning Message
FTOS#reset sfm 0
SFM0 is active. Resetting it might temporarily impact data traffic.
Proceed with reset [confirm yes/no]:yes
Feb 16 00:39:30: %RPM1-P:CP %TSM-5-SFM_DISCOVERY: Found SFM 0
FTOS#
This command does not permit resetting any SFM when the system has (max-1) SFM and switch fabric
is up
Introduced
Power on/off a line card
Introduced
(Figure
65-8).
Enter the slot number of the SFM to reset.
Range: 0 to 6
Enter the slot number of the SFM to reset.
Range: 0 to 7
(Figure
65-7).
E-Series Debugging and Diagnostics | 1547

Advertisement

loading