Chapter 5: Operations Page - Watlow Integrated Controller User Manual Rev C EZ-ZONE PM User Manual

Watlow ez-zone pm integrated controller user manual
Table of Contents

Advertisement

5

Chapter 5: Operations Page

To go to the Operations Page from the Home Page,
press both the Up ¿ and Down ¯ keys for three sec-
onds. [``Ai] will appear in the upper display and
[oPEr] will appear in the lower display.
• Press the Up ¿ or Down ¯ key to move through
the menus.
• Press the Advance Key ‰ to move to a submenu.
• Press the Up ¿ or Down ¯ key to move through
the submenus.
Home
Page
Operations Page
Parameters
[~~p~]
[``Ai]
[~~~I]
ˆ
ˆ
ˆ
[~~Sp]
[oPEr]
[``Ai]
[`ain]
<>
Hold both keys
Analog
Input 1
Process
for 3 seconds.
Input Menu
Value
Submenu
<
<
>
>
ˆ
Input 2
Same as above.
Submenu
ˆ
[`diO]
[~~~5]
ˆ
ˆ
[oPEr]
[`diO]
[`do; S ]
Digital In-
Digital I/O 5
Output State Event Input
put/Output
Submenu
Menu
<
>
<
>
ˆ Digital I/O 6
Same as above.
Submenu
ˆ
[LiM]
ˆ
[oPEr]
[`LL; S ]
[`Lh; S ]
Limit
Limit Low
Limit High
Menu
Set Point
Set Point
<
>
ˆ
[Mon]
ˆ
[oPEr]
[C; M A]
[`h; P r]
Monitor
Control
Heat Power
Menu
Mode Active
<
>
ˆ
[Loop]
ˆ
[oPEr]
[`r; E n]
[`r; t Y]
Loop Menu
Remote
Remote Set
Enable
Point Type
<
>
ˆ
[ALM]
[~~~I]
ˆ
ˆ
[oPEr]
[ALM]
[`A; L o]
Alarm
Alarm 1
Alarm Low
Menu
Set Point
Submenu
<
<
>
>
ˆ Alarm 2 to 4
Same as above.
Submenus
ˆ
[CUrr]
ˆ
[oPEr]
[`C; h i]
[`C; L o]
Current
Current High
Current Low
Menu
Set Point
Set Point
<
>
[P; S tA]
ˆ
ˆ
[oPEr]
[P; S tr]
[P; A Cr]
Profi le
Profi le Start Profi le
Status
Action
Menu
Request
<
>
®
Watl o w EZ-ZO N E
PM In t eg r a te d Co n t r o lle r
[`i; E r]
[`i; C a]
Input Error
Input
Status
Calibration
Offset
[`Ei; S ]
Status
[`C; P r]
[`C; S P]
[`Pu; A ]
Cool Power
Closed Loop
Process
Working Set
Value Active
Point
[`C; M ]
[A; t SP]
[`AUt]
[`C; S P]
Control
Autotune
Autotune
Closed Loop
Mode
Set Point
Request
Set Point
[`A; h i]
Alarm High
Set Point
[`CU; r ]
[`C; E r]
[`h; e r]
Current Read Current Error Heater Error
[`Stp]
[S; t YP]
[tg; S P]
[AC; S P]
Active Step
Active Step
Active Target
Active Set
Type
Set Point
Point
• Press the Advance Key ‰ to move through the pa-
rameters of the menu or submenu.
• Press the Infinity Key ˆ to move backwards
through the levels: parameter to submenu; sub-
menu to menu; menu to Home Page.
• Press and hold the Infinity Key ˆ for two seconds
to return to the Home Page.
Note: Avoid continuous writes within loops. Excessive writes to
EEPROM will cause premature EEPROM failure. The EEPROM is
rated for 1,000,000 writes.
Navigating the Operations Page
Note:
Some of these menus and parameters may not appear, depending
on the controller's options. See model number information in the
Appendix for more information.
If there is only one instance of a menu, no submenus will appear.
[`id; S ]
[`h; P b]
[`h; h Y]
Idle Set
Heat Propor-
Heat Hyster-
Point
tional Band
esis
[`S; t i]
[Ent1]
[``JC]
Step Time
Active Event
Jump Count
Remaining
Output
Remaining
(1 or 2)
28
[`C; P b]
[`C; h y]
[``ti]
[``td]
Cool Propor-
Cool Hyster-
Time Integral Time Deriva-
tional Band
esis
tive
Chapter 5 Operatio ns Page
[``db]
[`o; S P]
Dead Band
Open Loop
Set Point

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Integrated Controller User Manual Rev C EZ-ZONE PM and is the answer not in the manual?

This manual is also suitable for:

Ez-zone pm series

Table of Contents