User Manual
SIM Sample Cooler
for Agilent 1220 Infinity II LC System

Advertisement

Table of Contents
loading

Summary of Contents for Agilent Technologies 1220 Infinity II LC Series

  • Page 1 Scientific Instruments Manufacturer GmbH D-Oberhausen ● +49 (0)208/ 94 10 78-0 ● www.sim-gmbh.de User Manual SIM Sample Cooler for Agilent 1220 Infinity II LC System...
  • Page 2 Scientific Instruments Manufacturer GmbH D-Oberhausen ● +49 (0)208/ 94 10 78-0 ● www.sim-gmbh.de Document History Edition 06/2018 The information contained in this document is subject to change without notice. SIM GmbH makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose.
  • Page 3: Table Of Contents

    Scientific Instruments Manufacturer GmbH D-Oberhausen ● +49 (0)208/ 94 10 78-0 ● www.sim-gmbh.de CONTENT 1. SAFETY INSTRUCTIONS 1.1. Warnings 1.2. Meaning of the signal words 1.3. General Safety Instructions/ Informations générales de sécurité 2. SCOPE OF DELIVERY 2.1. LC 1220 90 40/ LC 1220 90 60/ LC 1220 94 60 2.2.
  • Page 4: Safety Instructions

    Scientific Instruments Manufacturer GmbH D-Oberhausen ● +49 (0)208/ 94 10 78-0 ● www.sim-gmbh.de 1. SAFETY INSTRUCTIONS NOTE The cooling module for the Agilent 1220 Infinity II LC system has to be mounted, started-up and serviced by fully trained and qualified personnel only, taking into consideration the generally recognized standard rules of technology.
  • Page 5: Meaning Of The Signal Words

    Scientific Instruments Manufacturer GmbH D-Oberhausen ● +49 (0)208/ 94 10 78-0 ● www.sim-gmbh.de 1.2. Meaning of the signal words Signal word/ Mot Meaning/ Signification de signalisation Direct danger to life or risk of severe physical injury if this danger DANGER/ is not avoided.
  • Page 6 Scientific Instruments Manufacturer GmbH D-Oberhausen ● +49 (0)208/ 94 10 78-0 ● www.sim-gmbh.de DANGER/ DANGER Dangerous Voltage! Tension électrique dangereuse! If the covers are attached correctly, no contact with dangerous tension is possible. Never remove the cover! Lorsque les capots sont fixés correctement, n’y a pas de contact avec tension dangereuse est possible.N'ouvrez jamais le capot de l’instrument! It is not allowed to insert objects into the housing.
  • Page 7 Scientific Instruments Manufacturer GmbH D-Oberhausen ● +49 (0)208/ 94 10 78-0 ● www.sim-gmbh.de CAUTION/ ATTENTION Personal Injury! Blessures corporelles! To prevent personal injury, do not grip into the needle area of the autosampler. Pour éviter tout risque de blessure, n'approchez pas vos doigts de l'aiguille pendant le fonctionnement de l'échantillonneur.
  • Page 8: Scope Of Delivery

    Scientific Instruments Manufacturer GmbH D-Oberhausen ● +49 (0)208/ 94 10 78-0 ● www.sim-gmbh.de 2. SCOPE OF DELIVERY 2.1. LC 1220 90 40/ LC 1220 90 60/ LC 1220 94 60 Fig. 1 Scope of delivery  cooling module (1) mounted at an 1220 Infinity II LC side wall, with power cable (not shown) ...
  • Page 9: Opt024 Driver For Openlab Cds

    Scientific Instruments Manufacturer GmbH D-Oberhausen ● +49 (0)208/ 94 10 78-0 ● www.sim-gmbh.de 2.5. OPT024 Driver for OpenLAB CDS 2.x  Software (LC 1220 10 24)  2 LAN cables (0.25 m and 2.0 m, LC 1220 10 75) 3. SITE REQUIREMENTS DANGER/ DANGER Absence of ground connection or use of unspecified power cord! Absence de raccordement à...
  • Page 10: Mode Of Operation

    Scientific Instruments Manufacturer GmbH D-Oberhausen ● +49 (0)208/ 94 10 78-0 ● www.sim-gmbh.de Bench space If using the cooling module together with the Agilent 1220 Infinity II LC System, the LC system needs an additional 15 cm of space on the left side (view from the front). Moreover, the module needs approximately 10 cm (3.9 in) at the rear and the left side for air circulation.
  • Page 11: Initial Operation

    Scientific Instruments Manufacturer GmbH D-Oberhausen ● +49 (0)208/ 94 10 78-0 ● www.sim-gmbh.de 5. INITIAL OPERATION 5.1. Connections Connect the cooling module with the Agilent 1220 Infinity System and the PC using patch cables (see also Fig. 2 and Tab. 1 LAN). Then use the power supply cable for the electrical connection.
  • Page 12: Software Installation

    Scientific Instruments Manufacturer GmbH D-Oberhausen ● +49 (0)208/ 94 10 78-0 ● www.sim-gmbh.de Connection Action the water level should be within the min/max marking when the Viewing Window pump is not working (possibly use a torch) 5.2. Software Installation (1) Finalize the installation of the Agilent 1220 Infinity system with performing a checkout run (User Manual G4280-90016, chapter 3).
  • Page 13 Scientific Instruments Manufacturer GmbH D-Oberhausen ● +49 (0)208/ 94 10 78-0 ● www.sim-gmbh.de User Manual SIM Sample Cooler_06/2018...
  • Page 14 Scientific Instruments Manufacturer GmbH D-Oberhausen ● +49 (0)208/ 94 10 78-0 ● www.sim-gmbh.de (2) When the installation is finished, start your Chromatographic data system and note the differences between ChemStation edition and EZChrom edition. User Manual SIM Sample Cooler_06/2018...
  • Page 15 Scientific Instruments Manufacturer GmbH D-Oberhausen ● +49 (0)208/ 94 10 78-0 ● www.sim-gmbh.de Configuration of the Sample Cooler (ChemStation edition): (3) At the instrument configuration screen select the SIM Sample Cooler and add this module using the Arrow button. With a click on the button Configure the device specific configuration dialogue is opened.
  • Page 16 Scientific Instruments Manufacturer GmbH D-Oberhausen ● +49 (0)208/ 94 10 78-0 ● www.sim-gmbh.de Device specific configuration (any OpenLAB CDS edition): (5) Click on Request Serial Number to test the connection of PC and Sample Cooler. (6) If the network settings are correct, the IP address is obtained automatically and the serial number is displayed.
  • Page 17 Scientific Instruments Manufacturer GmbH D-Oberhausen ● +49 (0)208/ 94 10 78-0 ● www.sim-gmbh.de TCP/IP settings: (7) Use the TCP/IP settings dialogue if there are two or more devices in the network or if there is no DHCP server in the current network and the default static IP address needs to be changed (or former changes have to be reverted).
  • Page 18 Scientific Instruments Manufacturer GmbH D-Oberhausen ● +49 (0)208/ 94 10 78-0 ● www.sim-gmbh.de (9) Equilibration Time: the SIM Cooler requires the temperature to be within a specifiable tolerance of the setpoint for this time to get ready. Switch Off after Sequence: cooling of the samples automatically ends when the sequence is finished.
  • Page 19: Software Settings For Opt021/022/024 (Openlab Cds Chemstation/Ezchrom/2.X)

    Scientific Instruments Manufacturer GmbH D-Oberhausen ● +49 (0)208/ 94 10 78-0 ● www.sim-gmbh.de 5.3.1. Software settings for OPT021/022/024 (OpenLAB CDS ChemStation/EZChrom/2.x) Fig. 3 Software settings In the CDS Instrument Control Window you see the SIM Tray Cooler in the dashboard. The method settings allow you to customize the behavior of the SIM Tray Cooler.
  • Page 20: Installation Of The Standalone Software (Opt023)

    Scientific Instruments Manufacturer GmbH D-Oberhausen ● +49 (0)208/ 94 10 78-0 ● www.sim-gmbh.de 5.3.2. Installation of the Standalone Software (OPT023) (1) Install the software file _SIM_LC1220_V and follow the instructions in the SETUP Setup Wizzard (similar procedure described in chapter 5.3). At the end of the installation you see the following window: Fig.
  • Page 21 Scientific Instruments Manufacturer GmbH D-Oberhausen ● +49 (0)208/ 94 10 78-0 ● www.sim-gmbh.de Assign a Fixed IP Address: The cooling module is set to a default fixed IP address – 192.168.254.99 (Class C network with a subnet mask of 255.255.255.0). Use File –...
  • Page 22: Software Settings For Opt023 (Standalone Software)

    Scientific Instruments Manufacturer GmbH D-Oberhausen ● +49 (0)208/ 94 10 78-0 ● www.sim-gmbh.de 5.3.3. Software settings for OPT023 (Standalone Software) When the standalone software for the Sample Cooler is open, you can enter the temperature requested into the field Temperature and confirm the value with S Fig.
  • Page 23 Scientific Instruments Manufacturer GmbH D-Oberhausen ● +49 (0)208/ 94 10 78-0 ● www.sim-gmbh.de Display Definition Transfer the set temperature to the cooling module Switch off only the Peltier element of the cooling module (the complete cooling module is switched on/off with the switch at the rear of the module, see Fig.
  • Page 24: Start Of The System

    Scientific Instruments Manufacturer GmbH D-Oberhausen ● +49 (0)208/ 94 10 78-0 ● www.sim-gmbh.de 6. START OF THE SYSTEM 6.1. Start of the cooling module (1) Switch on the cooling module using the ON/OFF switch (see Fig. 2). (2) Start the software and check the IP address. (3) Connect the software with the cooling module using the Connect button.
  • Page 25: Maintenance

    Scientific Instruments Manufacturer GmbH D-Oberhausen ● +49 (0)208/ 94 10 78-0 ● www.sim-gmbh.de OpenLAB Versions: In case of using OpenLAB driver, you can start the cooling module manually for the first equilibration before the sequence will be started. 7. MAINTENANCE Cautions and Warnings DANGER/ DANGER Risk of electrocution!
  • Page 26: Cleaning The Module

    Scientific Instruments Manufacturer GmbH D-Oberhausen ● +49 (0)208/ 94 10 78-0 ● www.sim-gmbh.de 7.1. Cleaning the module DANGER/ DANGER Risk of shock hazard! Risque d’électrocution! Liquid dripping into the electronic compartment of your module can cause shock hazard and damage the module. Le liquide s’égouttant dans le compartiment électronique de votre module peut provoquer un risque de choc et endommager le module.
  • Page 27 Scientific Instruments Manufacturer GmbH D-Oberhausen ● +49 (0)208/ 94 10 78-0 ● www.sim-gmbh.de Fig. 8 Water level (1) Check the water level at the viewing window (red arrow in Fig. 8) when the pump is not working. In order to improve visibility at the viewing window, light the water tank with a flashlight shining through the ventilation slots below.
  • Page 28: Troubleshooting

    Scientific Instruments Manufacturer GmbH D-Oberhausen ● +49 (0)208/ 94 10 78-0 ● www.sim-gmbh.de 8. TROUBLESHOOTING The error (see Tab. 3) occurs, because the Peltier element becomes too warm/hot:  When the Peltier element is cooled down, the cooler restarts automatically. Tab.
  • Page 29: Technical Data

    Scientific Instruments Manufacturer GmbH D-Oberhausen ● +49 (0)208/ 94 10 78-0 ● www.sim-gmbh.de 9. TECHNICAL DATA Tab. 4 Physical Specifications Type Specification Weight 5 kg Dimensions (H x W x D) 610 mm x 115 mm x 155 mm 100 - 240 V  Line voltage (fluctuations are not to exceed ±...