Western Digital Ultrastar Data60 Installation Manual page 43

Hide thumbs Also See for Ultrastar Data60:
Table of Contents

Advertisement

Installation Guide
Warning: The handles on the front of the chassis are not intended to be used to support the
weight of the Ultrastar Data60 . Lifting the unit by the chassis handles or trying to support the
unit on the handles can cause them to fail. This can cause serious damage to the unit or serious
bodily harm to those handling the unit. Always team lift the chassis by gripping the underside
of the unit, and never try to lift a chassis that is filled with drives.
Attention: This procedure utilizes "Right" and "Left" as to inform the user on actions related to
the installation. "Right" and "Left" will be in reference to where the user is positioned, whether
at the front or the rear of the installation space.
Step 1 : Remove the inner rail that is nested inside the rack rails.
a. Start by sliding the inner rail out of the outer/rack rail until the safety latch engages and the
inner rail will not extend further. It will only slide one way.
b. Press on the safety latch release spring located on the side of the rail and slide the inner rail
out the rest of the way.
Figure 11: Rail Safety Latch
Step 2 : Install the inner rail onto the chassis making sure they are installed on the correct side. Each inner
rail will read "R" for the right or "L" for the left embossed on the side that faces away from the
chassis. Right and Left are with reference to looking at the front of the enclosure.
a. Orient the inner rails so that the flat side is facing the enclosure and the side with the
grooves is facing away from the enclosure.
b. Align the keyholes on the inner rail to the mounting pegs on the side of the enclosure and
press the inner rail flush against the chassis. If the keyholes don't line up with the pegs, flip
the rail length-wise to see if this will align them.
Note: There are Right and Left rails and they must be installed as a set. Each inner
rail will read "R" for the right or "L" for the left embossed on the inside. Each outer
rail will read "R-Front" for the right or "L-Front" for the left. Right and Left refer to
when you are facing the front of the rack.
5.2 Ultrastar Data60 Installation Procedure
5. Installation
36