Ground Conductor; Restricted Access Location; Ground Block - Avaya G430 Deploying And Upgrading

Branch gateway
Hide thumbs Also See for G430:
Table of Contents

Advertisement

Warning:
If the installation location is greater than the length of the supplied secondary grounding
conductor from an approved ground, do not install the Branch Gateway or EM200 until a
licensed electrician is present to install a Supplementary Ground Conductor.
Related links
Ground conductor attachments

Ground conductor

A Supplementary Ground Conductor is provided with the equipment, and is constructed of 10
2
AWG (4.0 mm
) wire, with an insulated ring terminal crimped to one end that is suitable for the #8
(M4) stud/screw on the rear of the Branch Gateway or EM200 chassis.
The customer will need to provide a means of connecting this Supplementary Ground Conductor
to an approved ground according to Article 250 of the National Electrical Code (NEC).
Related links
Ground conductor attachments

Restricted Access Location

In Finland, Norway, and Sweden, the Branch Gateway and EM200s must be installed in a
Restricted Access Location, due to unreliable earthing concerns. A Restricted Access Location is
defined as access that can be gained by only Service Personnel or Customers who have been
instructed about the reasons for the restricted access and any safety precautions that must be
taken. In these cases, access to the Branch Gateway or EM200s is gained by the use of a tool
(such as a lock and key) or other means of security.
Warning:
For installations in Finland, Norway, and Sweden, the Branch Gateway and EM200 rely on two
ground connections (mains plug with an earth contact, and a Supplementary Ground
Conductor).
Related links
Ground conductor attachments

Ground block

A ground block, supplied by the customer and installed by an electrician, is available for use when
you are installing multiple Branch Gateway or EM200s. The ground block, intended for rack
mounting, has ten terminals available for terminating Supplementary Ground Conductors. Up to
ten Branch Gateway devices or EM200s can be grounded at the block installed close to the
July 2018
on page 34
on page 34
on page 34
Deploying and Upgrading Avaya G430 Branch Gateway
Comments on this document? infodev@avaya.com
Ground conductor attachments
35