Troubleshooting - Tecway Mecpower POLI GO AROUND Manual

Table of Contents

Advertisement

PCB board

11. Troubleshooting

Situation
Can not
insert the
coin
Light does
not work
Motor does
not work
Emergency
stop button
is invalid
No sound
No AC110V/220V input
Filter is not turned on
Machine has no reaction
No output from power supply box
Main board does not work
No card out
No card out
or more cards
from Card
More cards out
dispenser
No card error
Error on card
dispenser or
other
Card dispenser error
abnormal
situation
Other abnormal situation
Use a small brush to clean the dust and dirt.
Caused reason
There is no currency coin in
slot.
The sensitivity of the token
is too high.
Coin selector is damaged
The wire is disconnected
Light is damaged
Drive board is damgaed
The wire is disconnected
Solid state relay is damaged
Main board is damaged
Motor is damaged
Switch is disconnected
Switch is damaged
Speaker line is loosen
Volumn is too low
Speaker is damaged
Troubleshooting
Put the coin in currency slot.
Adjust the sensitivity of the token.
Change the coin selector.
Check the connection
Change the light
Repair or change the board
Check the connection
Change the solid state relay
Repair or change the board
Change the motor
Connect the switch
Change the switch
Connect the speaker
Open the coin door, adjust the volume
potentiometer on the main board
Change the speaker
Check the wiring and main power supply
Check and turn on the switch
Repair or change the power supply box
Change the main board
Refer to 9.3 to adjust card dispenser
Refer to 9.3 to adjust card dispenser
Add cards
Take out cards and restart. Refer to 9.3
to adjust card dispenser
Power recovery
其他请见下续表