Measures If There Is A Risk Of Frost - Fayat Group Bomag BW 138 AD-5 Operating Instruction, Maintenance Instruction

Tandem
Table of Contents

Advertisement

8.12.4 Measures if there is a risk of frost

Fig. 213
Fig. 214
Fig. 215
Protective equip-
ment:
1. Park the machine in secured condition
Ä Chapter 6.8 „Parking the machine in
secured condition" on page 121.
2. Open the drain cover on the water tank and
let all water run out.
3. Screw the drain cover back on.
4. Open the line connection in the articulation
area and let all water run out.
5. Close the line connection again.
6. Route the water line on the spraying pump
to the outside.
7. Open the drain valve (handle in flow direc-
tion) and let all water run out.
8. Switch on the water spraying system for a
short while to drain the water from the
pump.
9. Switch off the water spraying system.
10. Turn the ignition key back to position "0"
and pull it out.
BW 138 AD-5
Maintenance – As required
Working clothes
n
n
Protective gloves
205