Maintenance – Every 1000 operating hours
High pressure filter
Fig. 187
Final work
188
Protective equip-
ment:
1. Clean the area around the high pressure
filter.
2. Disconnect the hydraulic oil lines (1) from
the high pressure filter (2).
3. Remove the high pressure filter and
assemble the new high pressure filter, pay
attention to the flow direction (arrow).
4. Connect and tighten the hydraulic lines.
1. After the test run check the filters for leaks.
2. Dispose of hydraulic oil and filter environ-
mentally.
BW 138 AD-5
n
Working clothes
n
Protective gloves