Fayat Group Bomag BW 138 AD-5 Operating Instruction, Maintenance Instruction page 201

Tandem
Table of Contents

Advertisement

Fig. 204
Fig. 205
Fig. 206
3.
B-880-0032
Check the filling level on the water level
gauge, fill up if necessary.
4. Turn the ignition key to position "I".
B-ELE-0070
5.
B-SWI-1495
Turn the rotary switch for the water
spraying system to permanent spraying
(position "MAX").
ð The water spraying system is switched
on.
BW 138 AD-5
Maintenance – As required
NOTICE!
The spraying pump may get
damaged if the tank is empty!
– Always keep the water tank
filled with a sufficient amount
of water.
NOTICE!
The battery is being dis-
charged!
– Do not remain too long in
testing position.
In positions "1" to "4" the corre-
sponding spraying interval is
activated only once.
Then the water pump is
switched off again.