Maintenance – As required
Fig. 202
8.12.1.1
Replacing the safety element
Fig. 203

8.12.2 Checking the water spraying system

200
11. Press the reset button (1) for the yellow
piston on the maintenance indicator.
NOTICE!
Danger of engine damage!
The safety element must not be
cleaned and should not be used
again after it has been removed.
The safety element must be
replaced:
– if the air filter is damaged.
– at the latest after one year.
– if the air filter warning light
comes on again after the air filter
has been cleaned.
1. Remove the housing cover and pull the air
filter element off.
2. Pull the safety element out by turning it
lightly.
3. Push in a new safety element.
4. Insert the air filter and reassemble the
housing cover.
1. Park the machine on level and firm ground.
2. Shut down the engine.