Baud Rate
Stop Bits
Parity
RTS Control
DTR Control
Operational State
Passthrough State: Initiator
74
Rate of Passthrough port. Rate can be set to the following (Default =
9600): 110, 300, 600, 1200, 2400, 3600, 4800, 7200, 9600, 14400,
19200, 28800, 38400, 57600, 115200.
Number of stop bits for Passthrough port (1 or 2).
None, Even, Odd.
Force OFF, Force ON or Automatic. If automatic, the control will be
on when Passthrough is active. DTR and RTS are available for COM2
only for those VBrick models whose last digit is 3 or higher. Under no
conditions are RTS or DTR controls passed through end-to-end. All
control handling is local. When using a VBrick VCC-3 or VCC-4
camera, set this control to Automatic; when using a VBrick VCC-50i
camera, set this control to Force ON.
Force OFF, Force ON or Automatic. If automatic, the control will be
ON when Passthrough is active. Under no conditions are RTS or DTR
controls passed through end-to-end. All control handling is local.
When using a VBrick VCC-3 or VCC-4 camera, set this control to
Automatic; when using a VBrick VCC-50i camera, set this control to
Force ON.
Describes the current status of a Passthrough connection, including
error conditions, if any. Refer to the Network Status Section. This will
display "Active" if in Passthrough mode.