Toshiba 2000 V Series Manual page 150

Integrated controller module
Hide thumbs Also See for 2000 V Series:
Table of Contents

Advertisement

Chapter 6 RAS Information (Except for RAS Area in Communication Memory)
6
128
Module Status Code
0 (00H)
1 (01H)
2 (02H)
3 (03H)
4 (04H)
5 (05H)
6 (06H)
9 (09H)
10 (0AH)
(2) 7-Segment LED display status (02F3H to 0312H: 32 words)
The 02F3H to 0312H in the acknowledgement area represent 7-segment LED status
indications. They include DN611 status, network status, and slave device status
under DN611 management, and correspond to the error code indications on the
DN611 front panel. (Some of the statuses in Table 6-2 and Table 6-3 are not
displayed.). "NA = [ ]" in Table 6-8 shows a node address.
Table 6-8 7-Segment LED Status Indications
F
8 7
02F3H
NA=1
02F4H
NA=3
02F5H
NA=5
02F6H
NA=7
02F7H
NA=9
02F8H
NA=11
02F9H
NA=13
02FAH
NA=15
02FBH
NA=17
02FCH
NA=19
02FDH
NA=21
02FEH
NA=23
02FFH
NA=25
0300H
NA=27
0301H
NA=29
0302H
NA=31
Table 6-7 Module Status Codes
Normal status
Transmission not enabled
No data flow in the transmission line
Communication error
Scan list disagrees with the actual slave composition.
Network error
Network power error detected.
Busoff detected.
Duplicate node address detected.
0
NA=0
0303H
NA=2
0304H
NA=4
0305H
NA=6
0306H
NA=8
0307H
NA=10
0308H
NA=12
0309H
NA=14
030AH
NA=16
030BH
NA=18
030CH
NA=20
030DH
NA=22
030EH
NA=24
030FH
NA=26
0310H
NA=28
0311H
NA=30
0312H
model 2000 DeviceNet Module Manual (DN611/DN611A)
Description
F
8 7
NA=33
NA=32
NA=35
NA=34
NA=37
NA=36
NA=39
NA=38
NA=41
NA=40
NA=43
NA=42
NA=45
NA=44
NA=47
NA=46
NA=49
NA=48
NA=51
NA=50
NA=53
NA=52
NA=55
NA=54
NA=57
NA=56
NA=59
NA=58
NA=61
NA=60
NA=63
NA=62