Mounting Of Wall-Hung Model - SCAN 68 Series Assembly And Instruction Manual

Hide thumbs Also See for 68 Series:
Table of Contents

Advertisement

MOUNTING OF WALL-HUNG MODEL

Installation must be planned and executed in accordance with national and local building regulations.
The stove must only be fitted to a non-flammable wall. There must be no form of flammable component in the wall. In the case of
thin walls, nor must there be any behind the wall. The load-bearing capacity of the wall must be checked under all circumstances.
To ensure correct installation we recommend that a building expert be commissioned to plan and outline the installation with a
view to subsequent approval.
For wall installation we recommend using the wall brackets supplied.
If a chimney is installed on top of a wall-hung model, the chimney must be fully self-supporting. It must not rest on the
wood-burning stove. There must be a distance of at least 6 mm between the first section and the flange on the flue collar. Please
consult a specialist.
Scan A/S disclaims all liability for the installation of wall-hung wood-burning stoves.
Is only to be removed for external air supply
18
Replace with the inclosed
Type plate
Must be removed for wall fitting
Use either a drilling machine with Ø 6 mm drill or cutting
nippers to remove the illustrated plates
Must be removed, also in the
heat shield, for wall fitting
Wall mounted room heater fired by solid fuel
Minimum distance to combustible materials
Do not install on combustible materials
Side: 500 mm - Front: 950 mm
CO emission at 13% O2:
0,04%
556 mg/Nm³
Dust at 13% O2:
14 mg/Nm³
Flue gas temperature:
265°C
Nominal heat output:
5,5 kW
Efficiency:
80%
Fuel type:
Wood
Operation type:
Intermittent
The appliance can be operated in a shared flue.
Country
Classification
Certificate/Standard
Approved by
EUR
Intermittent
EN 13240
Teknologisk Institut
NS 3058
Teknologisk Institut
Norway
15a B-VG
ELAB-2100-AUS
Teknologisk Institut
Austria
Schweiz
LRV 11
VKF
Germany
Stufe 2
1. BlmSchV
Follow assembly- and instructions manual.
Use only recommended fuels.
Montage- und Bedienungsanleitung beachten.
1000
Scan A/S DK 5492 Vissenbjerg
04-2015