SMC Networks EX510-GPR1 Series Operation Manual page 11

Fieldbus system (profibus dp compliant)
Hide thumbs Also See for EX510-GPR1 Series:
Table of Contents

Advertisement

■Definition and terminology
Terms
A
Address
(Station address)
Attenuation factor
BF
B
Branch wiring
C
Class 2 master
Communication connector
Communication port
Communication speed
Connector lock pin
Conductor resistance
Current consumption
Current sink type
(NPN output)
Current source type
(PNP output)
D
Data rate
DIN rail
DIA
E
Enclosure (IP)
Enhancing diagnosis information
F
FG
Field bus
FREEZE function
G
GND
GSD file
A number allocated to identify the unit connected on the PROFIBUS DP
network. It is not allowed to be duplicated.
A dissipation of signal wave form in proportion to a length of communication
line. Normally, indicated by dB/ft (decibel per feet).
Abbreviation of BUS FAULT. It shows the communication of the GW unit.
A method to branch and connect a communication line and power line from
GW unit to SI unit and Input unit.
Master for control, commissioning, and configuration functions.
A connecting part to transmit a communication signal which goes and returns
between equipments in field bus.
A connection port to distribute a communication line and power line from GW
unit to SI unit and Input unit.
A speed at which data is sent and received in field bus etc. It depends on an
equipment (PLC etc.) at high side and is indicated by bps (bit per second).
A pin that prevents the connector for connecting load to be connected to SI
unit from coming off.
A electric resistance of a conductor. It is a value to show ease of current flow.
A current necessary to operate a product normally. In this case, the current
applied to a load is not included.
An output configuration of an input equipment which uses NPN transistor for
signal outputting part. It sinks current with input and that is the reason why it
is called sink.
An output configuration of an input equipment which uses PNP transistor for
signal outputting part. It sources current with input and that is the reason why
it is called source.
An amount of data which can be sent from one equipment to the other
equipment. Referred to as transmission speed of data.
A metallic rail conforming with DIN (German Federation) standard.
Abbreviation of Diagnosis. It shows the GW unit status.
An abbreviation of Ingress Protection. It is a standard related to protection of
a product from foreign matters (hand, steel ball, steel wire, dust, water etc.).
Diagnosis information from GW unit. It is composed of standard diagnosis
information provided with PROFIBUS DP and peculiar diagnosis information
to the GW unit.
An abbreviation of frame ground meaning a body ground. Used to show a
ground simply.
A standard which uses digital communication to transmit a signal between an
equipment running at factory and field (instrumentation and operation
equipment) and controller.
Function that input data of GW unit synchronizes with FREEZE command
from master.
An abbreviation of ground meaning reference voltage for signal. It has a
same potential level as a shield wire (sheath) of signal line and connector
and is referred to as a reference potential to transmit an electrical signal.
File which describes the master data of product.
-10-
Meaning
No.EX##-OMI0032-C

Advertisement

Table of Contents
loading

Table of Contents