Effect Of Operating States To Output; Electrical Isolation; Parameterizable Functions; Diagnostics I/O - Bosch Rexroth IndraControl S67 Series Application Description

Digital module 8 outputs
Hide thumbs Also See for Rexroth IndraControl S67 Series:
Table of Contents

Advertisement

20/69
Bosch Rexroth AG
Device Description
4.9.6

Effect of Operating States to Output

4.9.7

Electrical Isolation

4.9.8

Parameterizable Functions

4.9.9

Diagnostics I/O

Rexroth IndraControl S67 Digital Module 8 Outputs – 2.0 A (4×M12)
Switching frequency
Recommended minimum load
Parallel switching of 2 outputs
Type of protective circuit
Output resistance
*
Incorrect diagnostics can be caused by high switching frequen‐
cies with low load
Tab. 4-9:
Information on the actuator selection
CPU stop of PLC
Supply voltage under rated voltage toler‐
ance
Disconnection of supply voltage
Working method of the output
Response in case of overload
Tab. 4-10:
Effect of operating states on output
Channel - Channel
U
, U
, S-BUS
LS
A
Tab. 4-11:
Electrical isolation
Substitute value strategy (per channel)
Substitute value (per channel)
Diagnostics (per channel/per module)
Tab. 4-12:
Parameterizable functions
Per channel
Per channel
Per channel
Per module
Tab. 4-13:
Diagnostics I/O
DOK-CONTRL-S67DO8M122A-AP03-EN-P
Inductive load, approx. 20 Hz
Ohmic load, approx. 500 Hz
Lamp load, approx. 500 Hz
50 mA*
For power increase
For redundant load actuation
External protection (e.g. free-wheeling di‐
odes)
Maximum 0.4 Ω
Acc. to substitute value strategy
0 V status
0 V status
Non-storing
Automatic restart
No
500 V DC each
Switch substitute value/maintain last val‐
ue
0/1
Lock/unlock
Short circuit/actuator overload
Wire breakage of actuator
Overtemperature
Undervoltage (U
+ U
)
LS
A

Advertisement