Safety Devices; Information On The Operation; Unintended Use - Bosch Rexroth IndraControl S67 Series Application Description

Digital module 8 outputs
Hide thumbs Also See for Rexroth IndraControl S67 Series:
Table of Contents

Advertisement

10/69
Bosch Rexroth AG
Important Instructions on Use
2.2

Safety Devices

2.3

Information on the Operation

2.4

Unintended Use

Rexroth IndraControl S67 Digital Module 8 Outputs – 2.0 A (4×M12)
The S67-DO8-M12-2A module may only be used with the acces‐
sories and mounting parts listed in this documentation. Compo‐
nents that are not expressly mentioned must neither be attached
nor connected. The same applies to cables and lines.
Operation may only be carried out with the hardware component
configurations and combinations that are expressly specified and
with the software and firmware indicated and specified in the re‐
spective documentation and functional descriptions.
In case of non-compliance, the guarantee and warranty claims
shall automatically expire.
The S67-DO8-M12-2A module may only be operated under the mounting and
installation conditions, the position, and the ambient conditions (temperature,
degree of protection, humidity, EMC, etc.) specified in the related documenta‐
tion.
All products of the IndraControl S67 series are designed to meet the require‐
ments acc. to IP 67. This includes complete protection against accidental
contact with electrical voltage and currents – even when wet.
To integrate the IndraControl S67 components into your machine or system,
the following valid and applicable standards, guidelines and provisions have
to be complied with: e.g., BGV A 3, "Electrical Systems and Equipment", DIN
EN 418, EN 60204. The E-Stop devices shall remain effective in all operation
modes of the system and machine.
To protect against electromagnetic interferences:
Connect your system to protective earth (PE)
Ensure that the cable routing and the installation of the field bus, S-BUS
and supply cables as well as sensor and actuator cables are correctly
connected
The following measures have to be available for a 24 V supply:
Outer lightning protection on buildings
Inner lightning protection of supply and signal lines
Safe electrical separation of extra-low voltage 24 V DC through PELV
(protective extra-low voltage) or SELV (safety extra-low voltage) voltage
sources.
Using the S67-DO8-M12-2A module in areas of applications other than the
modules specified or described in the documentation and the technical speci‐
fications is considered as "unintended".
The S67-DO8-M12-2A module must not be used in case of
operating conditions which do not meet the specified ambient condi‐
tions. Operation under water, extreme temperature fluctuations or ex‐
treme maximum temperatures is prohibited
Use in household devices or devices belonging to the categories 1 to 7
and 10 specified in Appendix IA of the Directive 2002/96/EC ("WEEE")
DOK-CONTRL-S67DO8M122A-AP03-EN-P