DFI PR610-C621 User Manual page 36

Atx industrial motherboard
Hide thumbs Also See for PR610-C621:
Table of Contents

Advertisement

Advanced
H2O IPMI Configuration
X
X
X BMC Configuration X User Configuration
Configure the BMC's users in this sub-menu. The settings of all the 15 users are listed in the
lower part of the sub-menu.
InsydeH2O Setup Utility
Advanced
User Configuration
User ID
[1]
User Status
<Enabled>
User Password
Channel
[1]
Privilege
<Administrator>
Add current setting to list
-----------------------
User Id UserName
UserStatus Channel
Privilege
1
dfi
Enabled
1/2/3
Admin/Admin/Admin
2
Disabled
1/2/3
N/A/N/A/N/A
3
Disabled
1/2/3
N/A/N/A/N/A
4
Disabled
1/2/3
N/A/N/A/N/A
5
Disabled
1/2/3
N/A/N/A/N/A
6
Disabled
1/2/3
N/A/N/A/N/A
7
Disabled
1/2/3
N/A/N/A/N/A
8
Disabled
1/2/3
N/A/N/A/N/A
9
Disabled
1/2/3
N/A/N/A/N/A
10
Disabled
1/2/3
N/A/N/A/N/A
11
Disabled
1/2/3
N/A/N/A/N/A
12
Disabled
1/2/3
N/A/N/A/N/A
13
Disabled
1/2/3
N/A/N/A/N/A
14
Disabled
1/2/3
N/A/N/A/N/A
15
Disabled
1/2/3
N/A/N/A/N/A
F1
Help
↑ /↓
Select Item
Esc
Exit
←/→
Select Item
User ID
There are 15 BMC users available per system. Insert a number from 1 to 15 to select which
user ID is to be configured.
User Name
Insert an alias for the currently selected user.
User Status
Enable or disable the currently selected user.
User Password
Set up a password for the currently selected user. To clear any previously configured pass-
word, press Enter and leave the new password empty.
Channel
Select a LAN Channel to configure the privilege of the currently selected user.
Privilege
Select among Reserved, Callback, User, Operator, Administrator, and No Access. The privilege
of a user ID can be set differently in different channels.
Add current setting to list
Save the setting of the current user ID's previlege of the current channel.
User's Manual | PR610-C621
Rev. 5.0
E n a b l e / D i s a b l e I P M I S u p p o r t .
Note: If changing to enable, BMC
detailed information only valid
after rebooting.
F5/F6
Change Values
F9
Setup Defaults
Enter
Select
SubMenu
F10
Save and Exit
X
Advanced
H2O IPMI Configuration
X
X
X SDR List
InsydeH2O Setup Utility
Advanced
SDR List
SDR List Support
<Enabled>
ID
Sensor Name
Value
Unit
► 000
CPU Temp
48
► 002
PCH Temp
38
► 003
IO Temp
31
► 004
Riser Temp
30
► 005
3V BAT
2.997
V
► 006
CPU Status
0
Discrete
► 007
CPU Missing
0
Discrete
► 008
Physical Scrty
0
Discrete
► 009
Voltage Fault
0
Discrete
► 010
Pwr Unit Status
0
Discrete
► 011
BMC Watchdog
0
Discrete
► 012
IPMI Watchdog
0
Discrete
► 013
SMI Timeout
0
Discrete
► 014
System Event Log
0
Discrete
► 015
BMC FW Health
0
Discrete
F1
Help
↑ /↓
Select Item
Esc
Exit
←/→
Select Item
SDR List Support
Enable or disable the Sensor Data Record (SDR). All recorded information is listed in the lower
part of the page.
Chapter 3
BIOS SETTINGS
Rev. 5.0
F5/F6
Change Values
F9
Setup Defaults
Enter
Select
SubMenu
F10
Save and Exit
X
36

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sem2500Sem2510

Table of Contents