5
|
Application guidelines

5.2.1 Single room

Underfloor heating or radiators – Wired room thermostat
Installer reference guide
24
NOTICE
An overpressure bypass valve can be integrated in the system. Keep in mind that this
valve might not be shown on the illustrations.
Setup
A Main leaving water temperature zone
B One single room
a User interface used as room thermostat
The underfloor heating or radiators are directly connected to the indoor unit.
The room temperature of the main room is controlled by the user interface used
as a room thermostat (optional equipment EKRUDAS).
Configuration
Setting
Unit temperature control:
#: [2.9]
Code: [C-07]
Number of water temperature zones:
#: [4.4]
Code: [7-02]
Benefits
Highest comfort and efficiency. The smart room thermostat functionality can
decrease or increase the desired leaving water temperature based on the actual
room temperature (modulation). This results in:
-
Stable room temperature matching the desired temperature (higher comfort)
-
Less ON/OFF cycles (more quiet, higher comfort and higher efficiency)
-
Lowest possible leaving water temperature (higher efficiency)
Easy. You can easily set the desired room temperature via the user interface:
-
For your daily needs, you can use preset values and schedules.
-
To deviate from your daily needs, you can temporarily overrule the preset
values and schedules, or use the holiday mode.
A
B
a
2 (Room thermostat): Unit operation
is decided based on the ambient
temperature of the user interface.
0 (Single zone): Main
ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA/DJ3V+6V+9W7
Value
Daikin Altherma 3 R F
4P618947-1 – 2020.03