6
|
Application guidelines

6.2.1 Single room

Underfloor heating or radiators – Wired room thermostat
Installer reference guide
26
Setup
A Main leaving water temperature zone
B One single room
a User interface (delivered as accessory)
b Dedicated Human Comfort Interface (BRC1HHDA used as room thermostat)
For more information about connecting the electrical wiring to the unit, see
"9.2 Connections to the outdoor
The underfloor heating or radiators are directly connected to the outdoor unit –
or to the external backup heater kit, if there is one.
The room temperature is controlled by the dedicated Human Comfort Interface
(BRC1HHDA used as room thermostat).
Configuration
Setting
Unit temperature control:
#: [2.9]
Code: [C-07]
Number of water temperature zones:
#: [4.4]
Code: [7-02]
Benefits
Highest comfort and efficiency. The smart room thermostat functionality can
decrease or increase the desired leaving water temperature based on the actual
room temperature (modulation). This results in:
-
Stable room temperature matching the desired temperature (higher comfort)
-
Less ON/OFF cycles (more quiet, higher comfort and higher efficiency)
-
Lowest possible leaving water temperature (higher efficiency)
Easy. You can easily set the desired room temperature via the user interface:
-
For your daily needs, you can use preset values and schedules.
-
To deviate from your daily needs, you can temporarily overrule the preset
values and schedules, or use the holiday mode.
B
A
a
b
4
unit" [
 76].
2 (Room thermostat): Unit operation
is decided based on the ambient
temperature of the dedicated Human
Comfort Interface.
0 (Single zone): Main
Value
EWAA004~008D + EWYA004~008D
Packaged air-cooled water chillers
and packaged air to water heat pumps
4P688013-1B – 2022.09