Field settings table
Breadcrumb Field code
Setting name
Additional zone
3.7
[2-0D]
Emitter type
└─ Setpoint range
3.8.1
[9-05]
Heating minimum
3.8.2
[9-06]
Heating maximum
3.8.3
[9-07]
Cooling minimum
3.8.4
[9-08]
Cooling maximum
Additional zone
3.A
[C-06]
Thermostat type
└─ Delta T
3.B.1
[1-0C]
Delta T heating
3.B.2
[1-0E]
Delta T cooling
Space heating / cooling
└─ Operation range
4.3.1
[4-02]
Space heating OFF temp
4.3.2
[F-01]
Space cooling OFF temp
Space heating / cooling
4.4
[7-02]
Number of zones
4.5
[F-0D]
Pump operation mode
4.6
[E-02]
Unit type
4.7
[9-0D]
Pump limitation
Space heating / cooling
4.9
[F-00]
Pump outside range
4.A
[D-03]
Increase around 0°C
4.B
[9-04]
Overshoot
4.C
[2-06]
Antifrost
Tank
5.2
[6-0A]
Comfort setpoint
5.3
[6-0B]
Eco setpoint
5.4
[6-0C]
Reheat setpoint
5.6
[6-0D]
Heat up mode
└─ Disinfection
5.7.1
[2-01]
Activation
5.7.2
[2-00]
Operation day
5.7.3
[2-02]
Start time
5.7.4
[2-03]
Tank setpoint
5.7.5
[2-04]
Duration
Tank
5.8
[6-0E]
Maximum
5.9
[6-00]
Hysteresis
5.A
[6-08]
Hysteresis
5.B
Setpoint mode
└─ WD curve
(*1) *3V_(*2) *6V_
(*3) *9W_(*4) EHB*_
(*5) EHV*_
(*6) *X*_(*7) *H*
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W (*6)
R/O (*7)
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
(#) Setting is not applicable for this unit.
Range, step
Default value
0: Underfloor heating
1: Fancoil unit
2: Radiator
15~37°C, step: 1°C
25°C
[2-0D]=2:
37~65, step: 1°C
55°C
[2-0D]≠2:
37~55, step: 1°C
55°C
5~18°C, step: 1°C
5°C
18~22°C, step: 1°C
22°C
0: -
1: 1 contact
2: 2 contacts
3~10°C, step: 1°C
5°C
3~10°C, step: 1°C
5°C
14~35°C, step: 1°C
22°C
10~35°C, step: 1°C
20°C
0: 1 LWT zone
1: 2 LWT zones
0: Continuous
1: Sample
2: Request
0: Reversible (*6)
1: Heating only (*7)
0~8, step:1
0 : No limitation
1~4 : 50~80%
5~8 : 50~80% during sampling
6
0: Restricted
1: Allowed
0: No
1: increase 2°C, span 4°C
2: increase 4°C, span 4°C
3: increase 2°C, span 8°C
4: increase 4°C, span 8°C
1~4°C, step: 1°C
1°C
0: Disabled
1: Enabled
30~[6-0E]°C, step: 1°C
60°C
30~min(50, [6-0E])°C, step: 1°C
45°C
30~min(50, [6-0E])°C, step: 1°C
45°C
0: Reheat only
1: Reheat + sched.
2: Scheduled only
0: No
1: Yes
0: Each day
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
7: Sunday
0~23 hour, step: 1 hour
1
[E-07]≠
55~75°C, step: 5°C
1 :
70°C
[E-07]=1 : 60°C
60°C
[E-07]≠1: 5~60 min, step: 5 min
10 min
[E-07]=1: 40~60 min, step: 5 min
40 min
(*4) : 40~75°C, step: 1°C
60°C [E-07]=0
(*4) : 40~80°C, step: 1°C
80°C [E-07]=5
(*5) : 40~60°C, step: 1°C
60°C
2~40°C, step: 1°C
25°C
2~20°C, step: 1°C
10°C
0: Fixed
1: Weather dependent
3/10
Installer setting at variance with
default value
Date
Value