▪ Preparation of the installation, good practices, reference 7.2.3 Configuration wizard: System ........25 data, … 7.2.4 Configuration wizard: Backup heater ......27 ▪ Format: Digital files on http://www.daikineurope.com/support- 7.2.5 Configuration wizard: Main zone......... 27 and-manuals/product-information/ EHVH/X04+08S18+23EA/EJ Installation manual Daikin Altherma 3 R F 4P629083-1C – 2021.11...
Daikin website (publicly accessible). WARNING ▪ The full set of latest technical data is available on the Daikin The appliance shall be stored so as to prevent mechanical Business Portal (authentication required). damage and in a well-ventilated room without continuously...
WARNING DO NOT reuse refrigerant piping that has been used with any other refrigerant. Replace the refrigerant pipes or clean thoroughly. EHVH/X04+08S18+23EA/EJ Installation manual Daikin Altherma 3 R F 4P629083-1C – 2021.11...
Maximum refrigerant piping length between indoor 30 m unit and outdoor unit Make sure installation, servicing, maintenance and repair comply with instructions from Daikin and with applicable Minimum refrigerant piping length between indoor 3 m legislation and are executed ONLY by authorised persons.
SINGLE leak occurs. Example: If two indoor units are installed in the room, each with its own outdoor unit, then you have to consider the refrigerant charge of the largest indoor-outdoor combination. EHVH/X04+08S18+23EA/EJ Installation manual Daikin Altherma 3 R F 4P629083-1C – 2021.11...
Page 8
▪ Must be a permanent opening that cannot be closed. nv-min ▪ Must be ≥50% of A (minimum bottom opening area). nv-min ▪ Must be ≥1.5 m from the floor. (≥A nv-min Installation manual EHVH/X04+08S18+23EA/EJ Daikin Altherma 3 R F 4P629083-1C – 2021.11...
Total refrigerant charge (kg) (dm²) nv-min NOTICE If you remove the user interface panel, also disconnect the cables from the back of the user interface panel to prevent damage. EHVH/X04+08S18+23EA/EJ Installation manual Daikin Altherma 3 R F 4P629083-1C – 2021.11...
5 If you need access to the high voltage components, remove the high voltage switch box cover. 4.2.3 To close the indoor unit 1 Close the cover of the switch box. 2 Put the switch box back into place. Installation manual EHVH/X04+08S18+23EA/EJ Daikin Altherma 3 R F 4P629083-1C – 2021.11...
4 Reattach the side panel. Ensure the water can flow through the Liquid piping Ø6.4 mm (1/4") drain tube. Gas piping Ø15.9 mm (5/8") It is recommended to use a tundish to collect the water. ▪ Piping temper grade and thickness: EHVH/X04+08S18+23EA/EJ Installation manual Daikin Altherma 3 R F 4P629083-1C – 2021.11...
Fan coil unit (optional) (field supply) FHL1...3 Floor heating loop (field supply) Room thermostat (optional) (field supply) ▪ Valve towards expansion vessel. The valve towards the expansion vessel (if equipped) MUST be open. Installation manual EHVH/X04+08S18+23EA/EJ Daikin Altherma 3 R F 4P629083-1C – 2021.11...
Space heating/cooling water OUT (screw connection, 1") Space heating/cooling water IN (screw connection, 1") Domestic hot water OUT (screw connection, 3/4") EHVH/X04+08S18+23EA/EJ Installation manual Daikin Altherma 3 R F 4P629083-1C – 2021.11...
3 Upper switch box cover [2.9] Control [1.6] Room sensor offset 2 Connect the main power supply. In case of normal kWh rate power supply Interconnection Wires: (3+GND)×1.5 mm² cable (= main power supply) EHVH/X04+08S18+23EA/EJ Installation manual Daikin Altherma 3 R F 4P629083-1C – 2021.11...
To connect the backup heater power supply Backup heater Power supply Wires type 1N~ 230 V 2+GND 1N~ 230 V (6V3) 2+GND 3~ 230 V (6T1) 3+GND 3N~ 400 V 4+GND [9.3] Backup heater Installation manual EHVH/X04+08S18+23EA/EJ Daikin Altherma 3 R F 4P629083-1C – 2021.11...
Page 17
3~, 50 Hz L1 L2 L3 Factory-mounted cable connected to the contactor of the 230 V AC backup heater, inside the switch box (K1M) Field wiring (see table below) EHVH/X04+08S18+23EA/EJ Installation manual Daikin Altherma 3 R F 4P629083-1C – 2021.11...
2 Connect the valve control cable to the appropriate terminals as as shown in the illustration below. shown in the illustration below. NOTICE Wiring is different for a NC (normally closed) valve and a NO (normally open) valve. Installation manual EHVH/X04+08S18+23EA/EJ Daikin Altherma 3 R F 4P629083-1C – 2021.11...
2 Connect the domestic hot water pump cable to the appropriate terminals as shown in the illustration below. Wires connected to the alarm output Wire between X2M and A4P A4P Installation of EKRP1HBAA is required. EHVH/X04+08S18+23EA/EJ Installation manual Daikin Altherma 3 R F 4P629083-1C – 2021.11...
2 Connect the space cooling/heating ON/OFF output cable to the appropriate terminals as shown in the illustration below. Wires connected to the space cooling/heating ON/OFF output Wire between X2M and A4P A4P Installation of EKRP1HBAA is required. Installation manual EHVH/X04+08S18+23EA/EJ Daikin Altherma 3 R F 4P629083-1C – 2021.11...
2 Connect the safety thermostat (normally closed) cable to the appropriate terminals as shown in the illustration below. Note: The jumper wire (factory-mounted) must be removed from the respective terminals. EHVH/X04+08S18+23EA/EJ Installation manual Daikin Altherma 3 R F 4P629083-1C – 2021.11...
The 2 incoming Smart Grid contacts can activate the following Smart Grid modes: Smart Grid contact Smart Grid operation mode Free running Forced off Recommended on Forced on The use of a Smart Grid pulse meter is not mandatory: Installation manual EHVH/X04+08S18+23EA/EJ Daikin Altherma 3 R F 4P629083-1C – 2021.11...
Page 23
Sticker to put on the high voltage wires Wires between the relays and X5M (AWG22 ORG) Wires between the relays and X10M (AWG18 RED) High voltage Smart Grid contact 1 High voltage Smart Grid contact 2 EHVH/X04+08S18+23EA/EJ Installation manual Daikin Altherma 3 R F 4P629083-1C – 2021.11...
▪ Browse through the list of digits and change the the system after it is installed. selected digit. ▪ Move the cursor from left to right. ▪ Confirm the pin code and proceed. Installation manual EHVH/X04+08S18+23EA/EJ Daikin Altherma 3 R F 4P629083-1C – 2021.11...
European electricity grids. The type of backup heater must be set on the user interface. For units with a built-in backup heater, the type of heater can be viewed but not changed. EHVH/X04+08S18+23EA/EJ Installation manual Daikin Altherma 3 R F 4P629083-1C – 2021.11...
Page 26
Manual, the room frost protection function, the underfloor heating screed dryout function, and the water pipe antifreeze function will remain active even if the user does NOT confirm emergency operation. Installation manual EHVH/X04+08S18+23EA/EJ Daikin Altherma 3 R F 4P629083-1C – 2021.11...
Configuration wizard: Backup heater the storage temperature setpoint is higher than 50°C, Daikin recommends NOT to disable the backup heater The backup heater is adapted to be connected to most common second step because it will have a big impact on the European electricity grids.
▪ during storage comfort, to prioritize the domestic hot water preparation. When the tank temperature rises above this value, domestic hot water preparation and space heating/cooling are executed sequentially. Code Description [5.4] [6-0C] Reheat setpoint: ▪ 30°C~min(50,[6‑0E])°C EHVH/X04+08S18+23EA/EJ Installation manual Daikin Altherma 3 R F 4P629083-1C – 2021.11...
[2.4] Main zone > Setpoint WD heating, fixed cooling mode OR Weather dependent Main zone – Cooling [2.4] Main zone > Setpoint Weather dependent mode Additional zone – Heating Installation manual EHVH/X04+08S18+23EA/EJ Daikin Altherma 3 R F 4P629083-1C – 2021.11...
To fine-tune the weather-dependent curve: 2-points curve Code Description The following table describes how to fine-tune the weather- [8.3] Number that users can call in case of dependent curve of a zone or tank: problems. EHVH/X04+08S18+23EA/EJ Installation manual Daikin Altherma 3 R F 4P629083-1C – 2021.11...
Solar kit settings are shown but are NOT applicable for this unit. Settings shall NOT be used or changed. INFORMATION Depending on the selected installer settings and unit type, settings will be visible/invisible. Installation manual EHVH/X04+08S18+23EA/EJ Daikin Altherma 3 R F 4P629083-1C – 2021.11...
Next commissioning instructions in this chapter, a general ▪ Between the local supply panel and the indoor unit commissioning checklist is also available on the Daikin ▪ Between the indoor unit and the valves (if applicable) Business Portal (authentication required).
Result: The test run starts. It stops automatically when ready (±30 min). To stop the test run manually: — 1 In the menu, go to Stop test run. 2 Select OK to confirm. Installation manual EHVH/X04+08S18+23EA/EJ Daikin Altherma 3 R F 4P629083-1C – 2021.11...
▪ Show the user what to do for the maintenance of the unit. ▪ Explain the user about energy saving tips as described in the operation manual. EHVH/X04+08S18+23EA/EJ Installation manual Daikin Altherma 3 R F 4P629083-1C – 2021.11...
10 Technical data Technical data A subset of the latest technical data is available on the regional Daikin website (publicly accessible). The full set of latest technical data is available on the Daikin Business Portal (authentication required). 10.1 Piping diagram: Indoor unit...
Position in switch box (1) Main power connection (1) Main power connection English Translation For HP tariff For preferential kWh rate power supply Position in switch box Position in switch box EHVH/X04+08S18+23EA/EJ Installation manual Daikin Altherma 3 R F 4P629083-1C – 2021.11...
Page 38
Alarm output Changeover to ext. heat source Changeover to external heat source Max. load Maximum load Min. load Minimum load Only for demand PCB option Only for demand PCB option Installation manual EHVH/X04+08S18+23EA/EJ Daikin Altherma 3 R F 4P629083-1C – 2021.11...
Page 39
A8P: X801M: 4-5 add: X2M: 30-35a 4 core signal signal main & add: X2M: 3-4 Only for Human Comfort Interface 2 core 2×0.75 X5M: 11-12 A14P: P1-P2 user interface communication 4D130331C EHVH/X04+08S18+23EA/EJ Installation manual Daikin Altherma 3 R F 4P629083-1C – 2021.11...
, consider the value that corresponds to room "A =12 m ". room 10.4 Table 2 – Minimum floor area: indoor unit (kg) Minimum floor area (m²) H=600 mm 1.84 28.81 1.86 29.44 1.88 30.08 1.90 30.72 Installation manual EHVH/X04+08S18+23EA/EJ Daikin Altherma 3 R F 4P629083-1C – 2021.11...
Page 44
4P629083-1 C 00000000 4P629083-1C 2021.11 Verantwortung für Energie und Umwelt...