Technical data
8
8.1
tigSpeed continuous drive 45 hotwire
Performance specifications and guarantee only in connection with original spare and replacement
parts!
Hot wire current setting range
max.Hot wire voltage
Duty cycle DC at 40° C
35 %
60 %
100 %
Open circuit voltage (U
Open circuit voltage (U
Mains voltage (Tolerance)
Frequency
[2]
mains fuse
Mains connection cable
max. Connected load (S
Generator rating (Rec.)
Cos φ / efficiency
Protection class / Overvoltage
category
Contamination level
Insulation class / protection
classification
Residual current circuit breaker
[3]
Noise level
Ambient temperature
Machine cooling / Torch cooling
Wire feed speed
Factory-installed roll equipment
Drive
Wire spool diameter
Welding torch connection
Workpiece lead (min.)
Hot wire current
Welding current (I
EMC class
Safety marking
Standards used
Dimensions L / B / H
Weight
Load cycle: 10 min. (60 % DC ≙ 6 min. welding, 4 min. pause)
[1]
[2]
Safety fuses are recommended DIAZED xxA gG. When using automatic cutouts, the "C" trigger
characteristic must be used.
[3]
Noise level during idle mode and operation under standard load according to IEC 60974‑ 1 at the
maximum operating point.
099-000236-EW501
25.04.2019
[1]
)
0
)
r
)
1
[4]
)
2
tigSpeed continuous drive 45 hotwire
40 A to 180 A
10 V
180 A
150 A
130 A
98 V
<20 V
1 x 230 V (-40 % to +15 %)
50/60 Hz
1 x 10 A
H07RN-F3G2,5
2,7 kVA
4 kVA
0,99 / 86 %
Ⅰ / Ⅲ
H / IP 23
Type B (recommended)
<70 dB(A)
-25 °C to +40 °C
Fan (AF) / gas
0,3 m/min to 15 m/min
1,0/1,2 mm for steel wire
4 rollers (37 mm)
Standardised wire spools up to 300 mm
Decentralised connection
25 mm
95 mm
See declaration of conformity (appliance documents)
636 x 324 x 482 mm
25.0 x 12.8 x 19.0 inch
31,5 kg
69.4 lb.