Connecting The 701-Dl Digital Link - Edgetech 4200 User Hardware Manual

Side scan sonar system
Table of Contents

Advertisement

4. If the wired Ethernet connection, DC power source, or both will be used, connect the 8-pin plug
of the DC power/Ethernet cable to the DC INPUT ETHERNET connector of the 4200-P Portable
Topside Processor.
5. If a printer is used, connect the printer to a USB ETHERNET adapter connector of the laptop
computer.
6. If a navigation system is used, connect the navigation system output to COM 1 of the laptop
computer.
7. If an external source is used to trigger the 4200-P Portable Topside Processor, connect the trigger
output of this source to the EXT TRIGGER connector.
8. Do one of the following to connect power:
Connect the AC power cable to the AC INPUT connector and the AC power source.
Connect the red clamp of the DC power/Ethernet cable to the positive terminal of the DC
power source, and connect the black clamp to the negative terminal.
Connect both the AC and DC power sources, as described above.
9. Connect the laptop computer power supply to the computer and the AC power source.

3.8.5 Connecting the 701-DL Digital Link

To connect the 701-DL Digital Link:
1. Verify that the 701-DL Digital Link is not connected to AC power.
2. Verify that the tow cable is properly connected and attached to the tow vehicle, and then connect
the tow cable to the SEA CABLE connector.
3. Connect the Ethernet patch cable to the DATA connector of the 701-DL Digital Link and the
Ethernet connector of the user-supplied computer. This cable may be extended up to 100 feet
using a Category 5 Ethernet crossover or straight patch cable.
4. Set the IP address of your computer to 192.9.0.nnn, where nnn is any integer from 1 to 100, except
the reserved numbers: 192.9.0.22, 192.9.0.23, 192.9.0.225, 192.9.0.101, and 192.9.0.102.
5. If a printer is used, connect the printer to an available printer port.
6. If a navigation system is used, connect the navigation system output to an available serial
communications port.
7. If an external source is used to trigger the 701-DL Digital Link, connect the trigger output of this
source to the SYNC connector.
8. Connect the AC power cord to the LINE VAC connector and the AC power source.
4200 SIDE SCAN SONAR SYSTEM USER HARDWARE MANUAL
3-20
0004842_REV_N

Advertisement

Table of Contents
loading
Need help?

Need help?