Cleaning And Maintenance - SGM PALCO 3+ User Manual

Table of Contents

Advertisement

5
6
7
8
White balance setting:
1. Set "Color_Mode" at 220;
2. Adjust red, green and blue leds to achieve target white balance;
3. Set "Internal programs" at 71;
4. Set "Color_Mode" at 255, wait for 4 seconds until the target white balance will be stored.

CLEANING AND MAINTENANCE

The following points have to be considered during the inspection:
1) All the screws for installing the device or parts of it have to be tightly connected and must not
be corroded.
2) There must not be any deformations in the housing, color lenses, fixation and installation spots
(ceiling, suspension, trussing).
3)Mechanically moved parts must not show any trace of wearing and must not rotate with
unbalances.
4)The electric power supply cables must not show any damage, material fatigue or sediments.
Further instructions depending on the installation spot and usage have to be given by a skilled
installer and any safety problems have to be solved.
0-255
Green ( 0-Black , 255-100% Green )
Blue LED :
0-255
Blue ( 0-Black , 255-100% Blue )
Color Correction :
0-19
No function
20-255
20-2700K,255-7200K
Internal programs:
No function
0-10
11-40
Internal program 1
41-70
Internal program 2
71
Store Color_mode enable
72-100
Internal program 3
101-130
Internal program 4
131-160
Internal program 5
161-190
Internal program 6
191-220
Internal program 7
221-255
Internal program 8
Color Mode:
0-63
White balance disabled
64-189
White balance enabled
190-250
White balance disabled
251-255
Store a new white balance