SGM P Series User Manual
Hide thumbs Also See for P Series:

Advertisement

Quick Links

USER
MANUAL
P-S E R I E S
P-S E R I E S
P-2
P-2
P-2 P O I
P-2 P O I

Advertisement

Table of Contents
loading

Summary of Contents for SGM P Series

  • Page 1 USER MANUAL P-S E R I E S P-S E R I E S P-2 P O I P-2 P O I...
  • Page 2: Dimensions

    A digital version is available at www.sgmlight.com, or upon request via support@sgmlight.com. USER MANUAL REV. I © 2021 SGM Light A/S ® . The information in this document is subject to change without notice. SGM and all affiliated companies disclaim liability for any injury, damage, direct or indirect loss, consequen- tial or economic loss, or any other loss occurred by the use of, inability to use, or reliance on the information contained in this manual.
  • Page 3: Table Of Contents

    POI Permanent Outdoor Installation .......................... 16 Physical differences ......................................16 Configuration ........................................16 LED Indicator ........................................16 SGM Addressing Tool ......................................16 POI Spanner .........................................17 POI Tilt lock ...........................................17 Installation and rigging the P-2 POI ..................................17 Connecting DMX and AC power in POI ................................17 P-2 POI connection diagram ....................................18...
  • Page 4: Safety Information

    Read the following safety precautions carefully before unpacking, installing, powering, or operating the device. SGM fixtures are intended for professional use only. They are not suitable for household use. Les luminaires SGM sont impropre à l’usage domestique. Uniquement à usage professionnel.
  • Page 5: Before Installing This Product

    External cleaning and visual inspection of the fixture All users of SGM fixtures should regularly clean those parts of the fixture directly exposed to the elements, such as the external housing and front lenses. Additionally, all owners of SGM fixtures must periodically check the external housing of the fixture for structural breaks, components in bad shape, cracked lenses, or loose screws.
  • Page 6: Overview

    Overview The P-2/ P-2 POI is an IP65/ IP66-rated RGBW LED wash light with a small footprint and high output, designed for multiple applica- tions, including when wireless operation is essential (POI only). P-2 Series features: • A wash light, flood light, and a strobe light, weighing only 6.1 kg/ 13.4 lbs. •...
  • Page 7: Preparing For Installation

    Preparing for installation Unpacking Unpack the device and inspect it to ensure that it has not been damaged during transport. The P-2/ P-2 POI is shipped with: • 1 x Omega bracket with 1/4-turn fasteners (standard only). • 1 x Mounting bracket with fasteners (standard only). •...
  • Page 8 All SGM fixtures have locking points at the base for installation and rigging. In both standard and POI fixtures, the distance between the points from center to center is always 106 mm. However, while the base of the P-2 standard fixture includes 1/4 turn fastener camlocks to mount the omega brackets, the POI products come with M-10 nuts for M-10 screws.
  • Page 9: Tilt Lock

    If the fixture has been operating, always allow it to cool down for 15 minutes before handling. NOTE: In POI versions, SGM provides a POI Spanner with a pig-nose key for tilt adjustment. Either use the large or the small pig-nose key, depending on the type of fixture.
  • Page 10: Configuring The Device

    Configuring the device The P-2 Series can be set up by using the control panel and OLED multi-line display on fixture’s head or through RDM. Please note: In POI versions, there is no display mounted in the fixture. The adjustments are made through RDM. For more information see “RDM”...
  • Page 11: Connecting To A Dmx Control Device

    IP-rated XLR connectors suitable for outdoor use. Terminate the DMX-Out cable of the last fixture in the data link with a 120 ohm DMX termination. Note that SGM fixtures provide a passive DMX Thru signal as DMX Out instead of an active output signal. NOTE! For POI versions, please refer to “Connecting DMX and AC power in POI”...
  • Page 12: Setting A Static Color Manually

    PANEL 3 The fixture can operate in RGB calibrated mode which ensures that colors are compatible across the range of SGM fixtures. However, the P-2 Series also offers the ability to operate in RAW mode with full control of each color.
  • Page 13: Individual Fixture Settings

    Beam angle The P-2 can be equipped with 43°, 21°, and 15° lenses. Individual fixture settings Setting the dimming curve The setting of the dimming curve will determine the fixture’s behaviour, when changing the light intensity between 0% - 100%. Linear control provides uniform adjustment throughout dimming curve.
  • Page 14 Level 1 Level 2 Level 3 Level 4 Function INFO SENSORS Wireless Paired Displays wireless connection status. On Time Red 1 Display LED total power on time. (R, G, B, W). On Time Green 1 On Time Blue 1 Display LED total power on time. (R, G, B, W). On Time White 1 On Time Red 2 On Time Green 2...
  • Page 15: Rdm

    Confirm that the power is switched on; confirm that the cables are be off. plugged in. Main fuse is blown. Contact a certified SGM service partner, or support@sgmlight.com. Fixture suddenly turned off. Power was turned off. Check the power supply, switches and breakers.
  • Page 16: Poi Permanent Outdoor Installation

    This tool is available for download at www.sgmlight.com, and has to be used with the SGM USB 5-Pin-XLR Uploader cable POI if the luminaire does not use XLR connectors in the DMX cable, or the SGM USB uploader cable if the luminaire uses XLR 5-pin DMX connectors (available from your SGM dealer).
  • Page 17: Poi Spanner

    The P-2 POI has two M-10 nuts at the base that can be used for installation and rigging. The SGM Omega bracket (not included) or a customized bracket is needed to install the fixture. Review the dimensions below for integration with brackets or supports.
  • Page 18: P-2 Poi Connection Diagram

    Figure 19: Connecting DMX and AC Power in P-2 POI Connecting a wireless transmitter in POI In POI versions with wireless, it is necessary to pair the fixture with a new transmitter (by default, the fixture is linked to the SGM factory transmitter).
  • Page 19: Accessories

    Note: This accessory is suitable for both permanent outdoor and indoor installations. Figure 23: P-2 Series Anti-glare shields For further information and other possibilities see www.sgmlight.com or contact your local SGM dealer.
  • Page 20: Service

    9. Check that the sealing frame (gasket) is evenly visible all the way around the lens module. 10. Vacuum test the fixture after replacing the lens module to verify that the validity of ingress protection (IP) is kept - see “SGM...
  • Page 21: Maintenance

    Cleaning SGM fixtures with IP65 or IP66 rating do not require cleaning procedures inside the fixture. However, cleaning the front lens may be needed to achieve the maximum light output after exposure to dust, sand, or dirt. Exterior housing can also be cleaned to get a better look.
  • Page 22: Fixtures And Accessories