Cisco CRS-16 DC Installing And Removing page 70

Installing and removing power components

Advertisement

Removing a Modular Configuration Alarm Module
2. Slide the alarm module into the top left bay on the power shelf, with the display on the right side and the
handle on the left side.
3. Hand tighten the two captive screws on the alarm module.
4. Use the screwdriver to securely fasten the alarm module to the power shelf.
DETAILED STEPS
Step 1
Attach the ESD-preventive wrist strap to your wrist and connect its leash to one of the ESD connection sockets on the
front (PLIM) side of the chassis or a bare metal surface on the chassis.
Step 2
Slide the alarm module into the top left bay on the power shelf, with the display on the right side and the handle on the
left side.
Step 3
Hand tighten the two captive screws on the alarm module.
Step 4
Use the screwdriver to securely fasten the alarm module to the power shelf.
What to do next
After performing this task, install the modular configuration power modules and power module slot covers
(if required) and re-install the upper grille on the front (PLIM) side of the chassis. See
Configuration Power Module
Removing a Modular Configuration Alarm Module
This section describes how to remove the alarm modules, shown in the previous figure, from the modular
configuration power shelf installed in the LCC.
Required Tools and Equipment
You need the following tools to perform this task:
• ESD-preventive wrist strap
• 6-in. long number 1 Phillips screwdriver
Steps
To remove the alarm module, perform the following steps:
SUMMARY STEPS
1. Attach the ESD-preventive wrist strap to your wrist and connect its leash to one of the ESD connection
sockets on the front (PLIM) side of the chassis or a bare metal surface on the chassis.
2. Remove the upper grille on the front (PLIM) side of the chassis. For detailed instructions, see Installing
and Removing Exterior Cosmetic Components.
3. Use the screwdriver to loosen the two captive screws securing the alarm module to the power shelf.
4. Loosen by hand the panel fasteners on the alarm module.
5. Carefully slide the alarm module out of the power shelf.
Installing and Removing Power Components
70
and
Installing a Power Module Slot
Installing and Removing Power Components
Installing a Modular
Cover.