Goodrive100-PV Series Solar Pumping VFD
Function
code
consumption
LSB of VFD
P07.16
consumption
P07.27
Current fault type 0: No fault
Previous fault
P07.28
Previous 2 fault
P07.29
Previous 3 fault
P07.30
Previous 4 fault
P07.31
Previous 5 fault
P07.32
Previous 6 fault
P07.57
Previous 7 fault
P07.58
Previous 8 fault
P07.59
Previous 9 fault
P07.60
Previous 10 fault
P07.61
Previous 11 fault
P07.62
Name
Detailed illustration of parameters
power
VFD power consumption = P07.15*1000 +
P07.16
Setting range of P07.15: 0–65535 (*1000)
Setting range of P07.16: 0.0–999.9
power
Unit: kWh
1: Inverter unit U phase protection (OUt1)
type
2: Inverter unit V phase protection (OUt2)
3: Inverter unit W phase protection (OUt3)
type
4: ACC overcurrent (OC1)
5: DEC overcurrent (OC2)
type
6: Constant-speed overcurrent (OC3)
7: ACC overvoltage (OV1)
type
8: DEC overvoltage (OV2)
9: Constant-speed overvoltage (OV3)
type
10: Bus undervoltage (UV)
11: Motor overload (OL1)
type
12: VFD overload (OL2)
13: Input side phase loss (SPI)
14: Output side phase loss (SPO)
type
15: Overheat of the boost module (OH1)
16: Overheat fault of the inverter module
type
(OH2)
17: External fault (EF)
type
18: 485 communication fault (CE)
19: Current detection fault (ItE)
type
20: Motor antotune fault (tE)
21: EEPROM operation fault (EEP)
type
39
Function parameters
Default Modify
●
●
●
●
●
●
●
●
●
●
●
●
●
Need help?
Do you have a question about the Goodrive100-PV Series and is the answer not in the manual?
Questions and answers