Specifications For Cs 3-Phase - ClipperCreek CS 3-Phase Installation Manual

Table of Contents

Advertisement

SPECIFICATIONS FOR CS 3-PHASE

Line Input Power - Service Entrance
Voltage & Wiring:
Voltage Range:
Frequency:
CCID:
Current and
Output Power:
3 Phase
CS-20-3
CS-25-3
CS-30-3
CS-40-3
CS-50-3
CS-60-3
CS-70-3
CS-80-3
CS-90-3
CS-100-3
Dimensions:
Height
Width
Depth
Color:
Cable Length:
Weight
(without cable)
208V AC 3-phase, Wye-Connected - Use all
three phases and Safety Ground.
240V AC 3-phase, Delta-Connected - With
center-tap on one leg, contactor L1 and L2, the
"Stinger" must connect to the contactor center
position. L1 and L2 must measure 120V AC to
ground; the "Stinger" must measure 208V AC to
ground.
185V AC to 264V AC
50/60 Hz
20mA
at 240V
Breaker
20A
25A
30A
40A
50A
60A
70A
80A
90A
100A
304 mm (12in)
457 mm (18in)
203 mm (8in)
Gray
approximately 7.6mm (25ft)
16.5 kg (36 lbs)
CS 3-Phase Installation Manual
Max Current
16A
20A
24A
32A
40A
48A
56A
64A
72A
80A
Page 25
Max Output Power
6.7kW
8.3kW
10.0kW
13.3kW
16.6kW
20.0kW
23.2kW
26.6kW
29.9kW
33.2kW

Advertisement

Table of Contents
loading

Table of Contents