Table 6 - Comparison Of Curve Fitting Equations; Figure 27 - Thermistor Resistance Versus Temperature - Newport 8000 User Manual

Modular controller
Table of Contents

Advertisement

Chapter 4
In practice we have found that the constants A, B and C for virtually all common
thermistors lie within a narrow range. Consequently, we have defined the constants
C1, C2, C3 as follows:
1
Resistance of a 10K, Fenwal UUA41J1 thermistor.
2
Constants A' = 0.963 * 10
3
Constants
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Temperature Controller Module Operation

Figure 27 - Thermistor Resistance versus Temperature

---------Error T (°C)----------
1
R
T Actual
97072
-20.00
55326
-10.00
32650
0.00
19899
10.00
12492
20.00
10000
25.00
8057
30.00
5326
40.00
3602
50.00

Table 6 - Comparison of Curve Fitting Equations

-3
-4
, B' = 2.598 * 10
-3
A = 1.125 * 10
(C1 = 1.125)
-4
B = 2.347 * 10
(C2 = 2.347)
-7
C = 0.855 * 10
(C3 = 0.855)
First
Third Order
Order
Fit. Eq. 1
2
Fit. Eq. 2
-0.00
0.00
-0.00
-0.00
-0.00
0.00
0.00
0.00
-0.00
+3
C1 = A * 10
3
-0.32
-0.06
0.09
0.15
0.13
0.08
0.01
-0.20
-0.50