Operation and maintenance
May 2020
5.1.4
Device diagnostic screens
The following screens will show the device diagnostics depending on the state of the
device.
54
Device Information - Status: there is a critical error which
may prevent the device from operating correctly. Check
additional status screens for more information.
D E V
f A i l u r
PV Screen: process temperature, ohms or mV value
depending on how the device is configured
s n s r
1 0. 0 2
d e g c
SV Screen: terminal temperature value
T E R M
2 5. 0 0
d e g c
TV Screen: feature board temperature value
D E V
2 5. 2 5
d e g c
QV Screen: voltage reading at the power module
terminals
S u p l y
7. 2 1
v o l t s