5. Close housing cover and tighten to safety specification. Always ensure a proper seal
6. Position antenna vertically, either straight up or straight down. The antenna should
3.4.3
Remote mount
Procedure
1. Install sensor according to standard installation practices using an approved thread
2. Run wiring (and conduit, if necessary) from the sensor to the transmitter.
3. Pull wiring through the threaded conduit entry of the transmitter.
4. Attach sensor wiring to the terminals as indicated on the wiring diagram.
5. Connect Black Power Module.
Rosemount 648 Wireless
Figure 3-4: Installing Electronics Housing Cover
by installing the electronics housing covers so metal touches metal, but do not over
tighten.
be approximately 3 ft. (1 m) from any large structures or buildings, to allow clear
communication to other devices.
Figure 3-5: Possible Antenna Rotation
sealant on all connections.
Installation
May 2020