Quick Start Guide
00825-0100-4829, Rev DA
September 2016
Rosemount
644H Temperature
Transmitters
with F
Fieldbus
OUNDATION

Advertisement

loading

Summary of Contents for Emerson Rosemount 644H

  • Page 1 Quick Start Guide 00825-0100-4829, Rev DA September 2016 Rosemount 644H Temperature ™ Transmitters with F Fieldbus ™ OUNDATION...
  • Page 2: Table Of Contents

    September 2016 Quick Start Guide NOTICE This guide provides basic guidelines for the Rosemount 644. It does not provide instructions for detailed configuration, diagnostics, maintenance, service, troubleshooting, or installation. Refer to the Rosemount Reference Manual for more instruction. The manual and this guide are also available electronically on EmersonProcess.com/Rosemount.
  • Page 3: Mount The Transmitter

    Quick Start Guide September 2016 1.0 Mount the transmitter Mount the transmitter at a high point in the conduit run to prevent moisture from draining into the transmitter housing. 1.1 Typical connection head installation Head mount transmitter with DIN plate style sensor 1.
  • Page 4: Wire And Apply Power

    September 2016 Quick Start Guide 4. Pull the sensor wiring leads through the universal head and transmitter. Mount the transmitter in the universal head by threading the transmitter mounting screws into the universal head mounting holes. 5. Mount the transmitter-sensor assembly into the thermowell. Seal adapter threads with silicone tape.
  • Page 5 RTD and and mV ™ 1. Emerson provides 4-wire sensors for all single element RTDs. Use these RTDs in 3-wire configurations by leaving the unneeded leads disconnected and insulated with electrical tape. 2. The transmitters must be configured for at least a 3-wire RTD in order to recognize an RTD with a compensation loop.
  • Page 6: Ground The Transmitter

    September 2016 Quick Start Guide Note The power supply, filter, first terminator, and configuration tool are typically located in the control room. Note Each segment in a Fieldbus trunk must be terminated at both ends. 3.0 Ground the transmitter 3.1 Ungrounded thermocouple, mV, and RTD/Ohm inputs Each process installation has different requirements for grounding.
  • Page 7 Quick Start Guide September 2016 4. Ensure the sensor shield is electrically isolated from the surrounding grounded fixtures. A. Transmitter C. Fieldbus loop B. Sensor wires D. Shield ground point Note Connect shields together, electrically isolated from the transmitter. Option 3 1.
  • Page 8: Verify Tagging

    September 2016 Quick Start Guide A. Transmitter C. Fieldbus loop B. Sensor wires D. Shield ground point 4.0 Verify tagging 4.1 Commissioning (paper) tag COMMISSIONING TAG To identify which device is at a particular Device ID: 0011513051010001440-121698091725 location use the removable tag provided PD Tag: with the transmitter.
  • Page 9 Quick Start Guide September 2016 5.1 Transducer function block This block contains temperature measurement data for the sensor and the terminal temperature. It also includes information about sensor types, engineering units, damping and diagnostics. At a minimum, verify the parameters in Table Table 1.
  • Page 10 September 2016 Quick Start Guide Table 2. AI Block Parameters Parameter Comments Choices: CHANNEL 1. Sensor 1 2. Housing Temperature L_TYPE For most measurements, set to “DIRECT” Set desired measurement range and units. Units must be one of the following: Ohms XD_SCALE °C...
  • Page 11: Product Certifications

    Quick Start Guide September 2016 6.0 Product Certifications Rev 1.14 6.1 European Directive Information A copy of the EU Declaration of Conformity can be found at the end of the Quick Start Guide. The most recent revision of the EU Declaration of Conformity can be found at EmersonProcess.com/Rosemount.
  • Page 12 September 2016 Quick Start Guide Special Conditions for Safe Use (X): 1. When no enclosure option is selected, the Rosemount 644 Temperature Transmitter shall be installed in a final enclosure meeting type of protection IP20 and meeting the requirements of ANSI/ISA 61010-1 and ANSI/ISA 60079-0. 2.
  • Page 13 Quick Start Guide September 2016 I1 ATEX Intrinsic Safety Certificate: [Headmount HART]: Baseefa12ATEX0101X [Headmount Fieldbus/PROFIBUS]: Baseefa03ATEX0499X [Railmount HART]: BAS00ATEX1033X Standards: EN 60079-0: 2012, EN 60079-11: 2012 Markings: [HART]: II 1 G Ex ia IIC T6…T4 Ga; [Fieldbus/PROFIBUS]: II 1 G Ex ia IIC T4 Ga Table 4 for Entity Parameters and Temperature Classifications.
  • Page 14 September 2016 Quick Start Guide 5. A suitable certified Ex d or Ex tb enclosure is required to be connected to temperature probes with Enclosure option "N". 6. Care shall be taken by the end user to ensure that the external surface temperature on the equipment and the neck of DIN Style Sensor probe does not exceed 130 °C.
  • Page 15 Quick Start Guide September 2016 NG IECEx Type n – without enclosure Certificate: [Headmount Fieldbus/PROFIBUS, Railmount HART]: IECEx BAS 13.0053X [Headmount HART]: IECEx BAS 12.0070U Standards: IEC 60079-0: 2011, IEC 60079-15: 2010 Markings: [Headmount Fieldbus/PROFIBUS, Railmount HART]: Ex nA IIC T5 Gc (–40 °C ≤ ≤...
  • Page 16 September 2016 Quick Start Guide I2 INMETRO Intrinsic Safety Certificate: [Fieldbus]: UL-BR 15.0264X [HART]: UL-BR 14.0670X Standards: ABNT NBR IEC 60079-0:2008 + Corrigendum 1:2011, ABNT NBR IEC 60079-11:2011 Markings: [Fieldbus]: Ex ia IIC T* Ga (–60 °C ≤ T ≤ +** °C) [HART]: Ex ia IIC T* Ga (–60 °C ≤...
  • Page 17 Quick Start Guide September 2016 10. During installation, use and maintenance of this product, observe the following standards: GB3836.13-2013 “Electrical apparatus for explosive gas atmospheres Part 13: Repair and overhaul for apparatus used in explosive gas atmospheres” GB3836.15-2000 “Electrical apparatus for explosive gas atmospheres Part 15: Electrical installations in hazardous area (other than mines)”...
  • Page 18 September 2016 Quick Start Guide 2. Parameters: For Rosemount 644 Fieldbus, PROFIBUS, and Legacy 644 HART: Terminals of power supply (+, -) Max internal Max input Max input Max input parameters: Transmitter output voltage: current: power: (mA) (nF) (mH) 0.67/1 F,W (FISCO) 17.5 5.32...
  • Page 19 Quick Start Guide September 2016 problem in conjunction with manufacturer to avoid damage to the product. 7. During installation, use and maintenance of this product, observe the following standards: GB3836.13-2013 “Electrical apparatus for explosive gas atmospheres Part 13: Repair and overhaul for apparatus used in explosive gas atmospheres” GB3836.15-2000 “Electrical apparatus for explosive gas atmospheres Part 15: Electrical installations in hazardous area (other than mines)”...
  • Page 20 September 2016 Quick Start Guide Special Condition for Safe Use (X): 1. See certificate for special conditions. IM Technical Regulation Customs Union (EAC) Intrinsic Safety Certificate: RU C-US.GB05.B.00289 Standards: GOST R IEC 60079-0-2011, GOST R IEC 60079-11-2010 Markings: [HART]: 0Ex ia IIC T4…T6 Ga X; [Fieldbus/Profibus]: 0Ex ia IIC T4 Ga X Special Condition for Safe Use (X): 1.
  • Page 21 Quick Start Guide September 2016 6.4 Specification tables Table 3. Process Temperature T130 Max Ambient +40 °C +60 °C +60 °C +60 °C +60 °C +60 °C +70 °C Transmitter with LCD display 0-in. 55 °C 70 °C 95 °C 95 °C 95 °C 95 °C...
  • Page 22 September 2016 Quick Start Guide Figure 3. Rosemount 644 Temperature Transmitter Declaration of Conformity...
  • Page 23 Quick Start Guide September 2016...
  • Page 24 September 2016 Quick Start Guide...
  • Page 25 Quick Start Guide September 2016...
  • Page 26 September 2016 Quick Start Guide China RoHS Rosemount 644 List of Rosemount 644 Parts with China RoHS Concentration above MCVs Hazardous Substances Hexavalent Polybrominated Polybrominated Part Name Lead Mercury Cadmium Chromium biphenyls diphenyl ethers (Pb) (Hg) (Cd) (Cr +6) (PBB) (PBDE) Electronics Assembly...
  • Page 27 Quick Start Guide September 2016...
  • Page 28 Singapore 128461 Standard Terms and Conditions of Sale can be found at +65 6777 8211 www.Emerson.com/en-us/pages/Terms-of-Use.aspx The Emerson logo is a trademark and service mark of Emerson +65 6777 0947 Electric Co. Enquiries@AP.EmersonProcess.com Rosemount and Rosemount logotype are trademarks of Emerson Process Management.