Quick Start Guide
00825-0100-6129, Rev AB
February 2019
Rosemount
Wireless Dam Monitor
(WDM)
Special

Advertisement

loading

Summary of Contents for Emerson Rosemount 648

  • Page 1 Quick Start Guide 00825-0100-6129, Rev AB February 2019 ™ Rosemount Wireless Dam Monitor (WDM) Special...
  • Page 2: Table Of Contents

    February 2019 Quick Start Guide Rosemount WDM Rosemount WDM Hardware Revision ® HART Device Revision Device Install Kit/DD Revision Device Revision 1, DD Revision 1 or higher NOTICE This guide provides basic information for the Rosemount WDM special. It does not provide instructions for detailed configuration, diagnostics, maintenance, service, troubleshooting, or installations.
  • Page 3: Functionality

    Quick Start Guide February 2019 Functionality The intended use of this WDM special is to provide a solution for real-time monitoring of applications in underground water level and pressure management of an embankment dam to determine the stability of its structure. An Impress strain gauge pressure sensor is connected directly to the WDM which excites the sensor and measures the output.
  • Page 4 February 2019 Quick Start Guide Conduit entry Upon installation, ensure each conduit entry is either sealed with a conduit plug using approved thread sealant, or has an installed conduit fitting or cable gland with appropriate threaded sealant. Figure 2. Conduit Entry A.
  • Page 5: Physical Installation

    Quick Start Guide February 2019 Physical installation Vent tube installation The vent tube needs to be exposed to atmosphere in a dry environment. During installation, protect the end of the cable from water ingress. Do not remove the cover on the cable until the end is at the point of connection. Note The maximum bend radius for polyurethane cable is 1 inches.
  • Page 6: Verify Operation

    AMS Device Manager, a Rosemount WDM Device Dashboard (DD) is required. Contact the Rosemount Wireless Specialist Team (RMT-NA.SpecialistWireless@Emerson.com) to obtain the DD. To provide accurate sensor readings, values from each sensor data sheet need to be configured and stored in the Rosemount WDM Transmitter. Navigate to Configure >...
  • Page 7 Quick Start Guide February 2019 The communication status may be verified in the wireless device using the following Fast Key sequence. Table 1. Rosemount WDM Fast Key Sequence Function Fast Key sequence Menu items Comm, Join Mode, Neighbor Count, Advertisement Communications 3, 4 Count, Join Attempts...
  • Page 8: Troubleshooting

    February 2019 Quick Start Guide Troubleshooting If the device is not joined to the network after power up, verify the correct configuration of the network ID and join key, and verify that Active Advertising has been enabled on the Gateway. The network ID and join key in the device must match the network ID and join key of the Gateway.
  • Page 9 Quick Start Guide February 2019 as long as the batteries and the pack integrity are maintained. Care should be taken to prevent thermal, electrical or mechanical damage. Contacts should be protected to prevent premature discharge. Black power modules should be stored in a clean and dry area. For maximum black power module life, storage temperature should not exceed 86 °F (30 °C).
  • Page 10: Product Certifications

    RF spectrum. Nearly every country requires this type of product certification. Emerson is working with governmental agencies around the world to supply fully compliant products and remove the risk of violating country directives or laws governing wireless device usage.
  • Page 11 Quick Start Guide February 2019 Figure 6. Rosemount 648 Wireless Declaration of Conformity EU Declaration of Conformity No: RMD 1065 Rev. K Rosemount, Inc. 8200 Market Boulevard Chanhassen, MN 55317-9685 declare under our sole responsibility that the product, Rosemount™ 648 Wireless Temperature Transmitter manufactured by, Rosemount, Inc.
  • Page 12 February 2019 Quick Start Guide EU Declaration of Conformity No: RMD 1065 Rev. K EMC Directive (2014/30/EU) Harmonized Standards: EN 61326-1: 2013 EN 61326-2-3: 2013 Radio Equipment Directive (RED) (2014/53/EU) Harmonized Standards: EN 300 328 V2.1.1 EN 301 489-1 V2.2.0 EN 301 489-17: V3.2.0 EN 61010-1: 2010 EN 62311: 2008...
  • Page 13 Quick Start Guide February 2019 China RoHS Rosemount 648 List of Rosemount 648 Parts with China RoHS Concentration above MCVs Hazardous Substances Hexavalent Polybrominated Polybrominated Part Name Lead Mercury Cadmium Chromium biphenyls diphenyl ethers (Pb) (Hg) (Cd) (Cr +6) (PBB)