Treel Fg Duty Adjustment (Vc-308 Board); Read Clock Fo Adjustment (Vc-308 Board) - Sony DCR-IP210 Adjustment

Hide thumbs Also See for DCR-IP210:
Table of Contents

Advertisement

DCR-IP210/IP210E/IP220/IP220E

2. Treel FG Duty Adjustment (VC-308 Board)

Set the Treel FG signal duty cycle to 50%.
Mode
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note1: Don't open the cassette compartment during this adjustment.
Note2: The data of page: 0, address: 10 must be "00".
Preparation:
Order Page Address Data
1
2
0
01
3
9
74
4
9
81
5
9
CA
6
Adjusting method:
Order Page Address Data
1
0
01
2
C
2C
3
3
90
4
5
3
92
6
C
2C
7
8
9
9
74
10
9
81
11
9
CA
12
3
90
13
0
01
14
CUE mode without a cassette
Data of page: 3, address: 92
Adjustment remote commander
C
2C
70 to 90
Procedure
Close the cassette compartment
without inserting a cassette.
01
Set the data.
01
Set the data, and press PAUSE
button.
01
Set the data, and press PAUSE
button.
03
Set the data, and press PAUSE
button.
Turn off the power supply of the
unit and turn on again.
Procedure
01
Set the data.
80
Set the data, and press PAUSE
button.
01
Set the data, and press PAUSE
button.
Enter the CUE mode without a
cassette.
When the data satisfies the
specified value, proceed to step 8.
When the data doesn't satisfy
the specified value, proceed to
step 6.
Change the data, and press
PAUSE button.
Return to step 4.
Enter the STOP mode.
00
Set the data, and press PAUSE
button.
00
Set the data, and press PAUSE
button.
02
Set the data, and press PAUSE
button.
00
Set the data, and press PAUSE
button.
00
Set the data.
Turn off the power supply of the
unit and turn on again.

3. Read Clock fo Adjustment (VC-308 Board)

Set the read clock center frequency of IC801.
Mode
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note1: Don't open the cassette compartment during this adjustment.
Note2: The data of page: 0, address: 10 must be "00".
Preparation:
Order Page Address Data
1
2
0
01
3
9
74
4
9
81
5
Adjusting method:
Order Page Address Data
1
0
01
2
3
3
00
4
3
01
5
6
9
74
7
9
81
8
0
01
9
6-56
Play back mode without a cassette
Data of page: 3, address: 01
Adjustment remote commander
C
6C
00
Procedure
Close the cassette compartment
without inserting a cassette.
01
Set the data.
01
Set the data, and press PAUSE
button.
01
Set the data, and press PAUSE
button.
Turn off the power supply of the
unit and turn on again.
Procedure
01
Set the data.
Enter the play back mode
without a cassette.
0F
Set the data, and press PAUSE
button.
Check that the data changes to "00".
If the data changes to "FF",
there are errors (Time-out).
Enter the STOP mode.
00
Set the data, and press PAUSE
button.
00
Set the data, and press PAUSE
button.
00
Set the data.