Servo And Rf System Adjustment; Cap Fg Duty Adjustment (Vc-242D Board); T Reel Fg Duty Adjustment (Vc-242D Board); Pll F & Lpf F Adjustment (Vc-242D Board) - Sony DSR-PD150P Service Manual

Hide thumbs Also See for DSR-PD150P:
Table of Contents

Advertisement

3-3.

SERVO AND RF SYSTEM ADJUSTMENT

Before perform the servo and RF system adjustments, check that
the specified value of "27 MHz Origin Oscillation Adjustment" of
"CAMERA SYSTEM ADJUSTMENT" is satisfied.
Adjusting Procedure:
1.
Cap FG duty adjustment
2.
T-reel FG duty adjustment
3.
PLL f
& LPF f
adjustment
0
0
4.
Switching position adjustment
5.
AGC center level
6.
APC & AEQ adjustment
7.
PLL f
& LPF f
final adjustment
0
0

1. Cap FG Duty Adjustment (VC-242D board)

Set the Cap FG signal duty cycle to 50% to establish an appropriate
capstan servo. If deviated, the uneven rotation of capstan and noise
can occur.
Measurement Point
Display data of page: 3, address: 03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
16
Specified Value
00
Adjusting method:
Order Page Address Data
1
2
0
01
01
3
3
01
1B
4
3
02
5
3
03
6
0
01
00
Note: If the data is "01", adjustment has errors or the mechanism deck is
defective.
Procedure
Close the cassette compartment
without inserting a cassette.
Set the data.
Set the data, and press PAUSE
button.
Check that the data changes in
the following order.
"1B" → "2B" → "00"
Check that the data is "00".
(Note)
Set the data.

2. T reel FG Duty Adjustment (VC-242D board)

Adjust the take-up reel FG signal duty cycle to an appropriate value
so that the correct T-reel FG signal is obtained.
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Adjusting method:
Order Page Address Data
1
2
0
01
3
3
01
4
3
02
5
3
03
6
0
01
Note: If the data is "02", adjustment has errors or the mechanism deck is
defective.
3. PLL f
& LPF f
Adjustment (VC-242D board)
0
0
Mode
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Adjusting method:
Order Page Address Data
1
0
01
2
3
01
3
3
02
4
3
03
5
0
01
Note: If the data is other than "00", there are errors.
For the error contents, see the following table. (For the bit values,
refer to "5-4. SERVICE MODE", "4-3. 3. Bit value discrimination".)
Bit value of page: 3,
address: 03 data
bit 4 = 1
bit 5 = 1
bit 6 = 1
bit 3 = 1
bit 2 = 1
5-64
Display data of page: 3, address: 03
Adjustment remote commander
C
17
00
Procedure
Close the cassette compartment
without inserting a cassette.
01
Set the data.
1C
Set the data, and press PAUSE
button.
Check that the data changes in
the following order.
"1C" → "2C" → "00"
Check that the data is "00".
(Note)
00
Set the data.
VTR stop
Display data of page: 3, address: 03
Adjustment remote commander
C
1F, 20, 22, 29
Bit2, bit3 and bit6 are "0"
Procedure
01
Set the data.
30
Set the data, and press PAUSE
button.
Check that the data changes to
"00".
Check that the data is "00".
(Note)
00
Set the data.
Error contents
PLL f
even channel is defective
0
PLL f
odd channel is defective
0
LPF f
is defective
0
PLL f
final adjustment is defective
0
PLL f
final adjustment time-out
0