COVER
COVER
3-2.

SYSTEM CONTROL SYSTEM ADJUSTMENT

1. Initialization of 4, 8, 9, A, B, C, D, E, F, 1B, 1E, 1F

Page Data

If the 4, 8, 9, A, B, C, D, E, F, 1B, 1E, 1F page data is erased due to
some reason, perform "1-2. INITIALIZATION OF 4, 8, 9, A, B, C,
D, E, F, 1B, 1E, 1F PAGE DATA", of "6-1. CAMERA SECTION
ADJUSTMENT"
Note: When reading or writing the 1B, 1E, 1F page data, select page: 0,
address: 10, and set data: 01, then select B, E or F page. The 1B. 1E
or 1F page can be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
"00".

2. Touch Panel Adjustment

Adjust the calibration of the touch panel.
Mode
VTR stop
Signal
Arbitrary
Adjustment Page
A
Adjustment Address
90 to 93
Note1: Close the LCD panel with reversed LCD screen. (Close the LCD
panel so that the LCD screen can be seen.)
Note2: Perform this adjustment with observing the screen from the front.
Note3: The data of page: 0, address: 10 must be "00".
Adjusting method:
1)
Select page: 7, address: 05, and set data: 01.
2)
Using a stylus, push the center of "X" indicated in the part A.
3)
Using a stylus, push the center of "X" indicated in the part B.
4)
Using a stylus, push the center of "X" indicated in the part C.
5)
Select page: 7, address: 05, and check that the data is "00".
A
Fig. 6-3-4.
C
B
DCR-IP210/IP210E/IP220/IP220E

3. Serial No. Input

Write the serial No. and model code in the EEPROM (nonvolatile
memory). Convert the serial No. on the name plate from decimal to
hexadecimal, and write in the EEPROM.
Note: The data of page: 0, address: 10 must be "00".
Adjustment Page
Adjustment Address
Input method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Read the serial No. on the name plate, and take it as D
Example: If the serial No. is 77881.
D
=77881
1
Note: Use six digits of the low rank when a serial No. is more than
seven digits.
3)
Obtain D
and H
corresponding to D
2
1
Example: If D
D
=D
2
H
=FE
1
D
(Decimal)
D
1
000001 to 065535
D
1
065536 to 131071
D
1
131072 to 196607
D
1
4)
Input H
to page: 9, address: 09. (Model code input)
1
Example: If H1 is "FE".
Select page: 9, address: 09, set data: FE, and press the
PAUSE button.
5)
Obtain the maximum decimal not exceeding D
3-3., and take this as D
Example: If D
is "12345".
2
D
=12288
3
6)
Obtain the hexadecimal corresponding to D
3., and take this as H
Example: If D
is "12288".
3
H
=3000
3
7)
Obtain the difference D
calculation, 0
D
4
D
= D
–D
4
2
3
Example: If D
D
=12345–12288=57
4
8)
Convert D
to hexadecimal, and take this as H
4
(Refer to "Hexadecimal-decimal conversion table" in "6-4.
Service Mode".)
Example: If D
is "57".
4
H
=39
4
9)
Input the upper 2 digits of H
Example: If H
is "3000".
3
Select page: 9, address: 0A, set data: 30, and press the
PAUSE button.
10) Input H
to page: 9, address: 0B.
4
Example: If H
is "39".
4
Select page: 9, address: 0B, set data: 39, and press the
PAUSE button.
11) Select page: 0, address: 01, and set data: 00.
6-53
9
09, 0A, 0B
from Table. 6-3-2.
1
is "77881".
1
-65536=12345
1
H
(Hexadecimal)
1
(Decimal)
2
(Service model code)
FE
–65536
FE
–131072
FE
Table. 6-3-2.
from Table. 6-
2
.
3
from Table. 6-3-
3
.
3
between D
and D
4
2
3
255)
is "12345" and D
is "12288".
2
3
.
4
to page: 9, address: 0A.