Timing Atf Center Value Adjustment (Vc-308 Board); Preparations Before Adjustments - Sony DCR-IP210 Adjustment

Hide thumbs Also See for DCR-IP210:
Table of Contents

Advertisement

DCR-IP210/IP210E/IP220/IP220E
6. Timing ATF Center Value Adjustment
(VC-308 Board)
Adjustment is performed to get the data for ATF servo.
Mode
Signal
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note1: The data of page: 0, address: 10 must be "00".
Adjusting method:
Order Page Address Data
1
0
01
2
9
9A
3
4
3
0A
5
3
0B
6
9
9A
7
0
01
Note2: If the data changes to "FF", adjustment has errors. Contents of the
error is written into page: 3, addresses: 0C. See the following table.
Data of page: 3,
address: 0C
Mechanism mode error (For example, the
01
adjustment is performed in the mode except
for the play back mode.)
Adjustment mode error (The data of page: 3,
02
address: 0A was changed during the
adjustment.)
03
Sync isn't played back at all.
04
Mch sync error (Time out in 30 sec.)
05
Pch sync error (Time out in 30 sec.)
06
Mch and Pch error (Time out in 30 sec.)
Playback
A recorded tape
Data of page: 3, address: 0B
Adjustment remote commander
C
70 to 77
00
Procedure
01
Set the data.
64
Set the data, and press PAUSE
button.
Enter the play back mode.
40
Set the data, and press PAUSE
button.
Check that the data changes to "00".
If the data changes to "FF",
there are errors. (Note2)
16
Set the data, and press PAUSE
button.
00
Set the data.
Contents of error
7. AGC Adjustment and AEQ & LMS Adjustment
Note: The following adjustments should be carried out upon completion
of "Switching Position Adjustment". And perform "Timing ATF
Center Value Adjustment" before perform the following adjustments.
7-1.

Preparations Before Adjustments

Mode
Subject
Note: The data of page: 0, address: 10 must be "00".
Adjusting method:
Order Page Address Data
1
0
01
2
C
6D
3
3
00
4
3
01
5
6
6-58
Camera recording
Arbitrary
Procedure
01
Set the data.
When the data is "00", proceed
to step 6.
When the data is except for
"00", proceed to step 3.
1E
Set the data, and press PAUSE
button.
Check that the data is "00".
Turn off the power supply of the
unit and turn on again.
Record the camera signal for 3
minutes.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcr-ip210eDcr-ip220Dcr-ip220e

Table of Contents