1-1-2.

Preparations

Note1: For details of how remove the cabinet and boards, refer to "2.
DISASSEMBLY".
Note2: When performing only the adjustments, the lens block and boards
need not be disassembled.
Note3: Before performing the adjustments, check the data of page: 0,
address: 10 is "00". If not, set data: 00 to this address.
1) Connect the equipment for adjustments according to Fig. 6-1-3.
Note4: Be careful not to touch the ST-076 board (Flash drive circuit).
Because there is a danger of electric shock when the ST-076 board
is handled by hand.
Note5: Perform "Zoom Key Center adjustment" and "Flange back
Adjustment" under the condition that the zoom switch (RV4001
of the control switch block (SS-2980)) is surely connected.
Note6: As removing the control switch block (PW-2980)) means removing
the lithium 3V power supply (BT4101 on the control switch block
(PW-2980)), data such as date, time, user-set menus will be lost.
After completing adjustments, reset these data.
But the self-diagnosis data and the data on history of use (total
drum rotation time etc.) will be kept even if the lithium 3V power
supply is removed. (Refer to "6-4. Service Mode" for the self-
diagnosis data and the data on history of use.)
Note7: Setting the "Forced Camera Power ON" Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press the PAUSE
button of the adjustment remote commander.
The above procedure will enable the camera power to be turned
on with the control switch block (PW-2980) removed. After
completing adjustments, be sure to exit the "Forced Camera
Power ON Mode".
Note 8: Exiting the "Forced Camera Power ON" Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 0, address: 01, and set data: 00.
Pattern box
Front of the lens
6-6
1.5 m
Fig. 6-1-2.