COVER
COVER
1-4.
COLOR ELECTRONIC VIEWFINDER
SYSTEM ADJUSTMENT
Note1: When replacing the LCD unit, be careful to prevent damages
caused by static electricity.
Note2: Before performing the adjustments, check the data of page: 0,
address: 10 is "00". If not, set data: 00 to this address.
Note3: When performing the viewfinder system adjustments with the LCD
panel open, perform the following data setting before the
adjustments. (This data setting will be canceled, when the
automatic adjustment is done.)
1) Select page: 3, address: 00, set data: 01 and press PAUSE
button.
2) Select page: 3, address: 02, and set data: 02.
Reset the data after completing adjustment.
1) Select page: 3, address: 00, set data: 00 and press PAUSE
button.
2) Select page: 3, address: 02, and set data: 00.
Switch setting:
LCD panel .................... Closed (Close the LCD panel so that
the LCD screen can't be seen. Note3)
DCR-IP210/IP210E/IP220/IP220E
[Measuring points]
The measuring points for manual adjustment are Pin eg (EXT DA)
and Pin ws (VG) of IC2201 of DI-087 board.
48
1
12
13
6-37
DI-087 board (SIDE B)
37
36
IC2201
25
24
Fig. 6-1-17.