Auto White Balance Adjustment - Sony DCR-IP210 Adjustment

Hide thumbs Also See for DCR-IP210:
Table of Contents

Advertisement

14. Auto White Balance Adjustment

Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility will
be poor.
Subject
Clear chart
(Color reproduction adjustment frame)
Filter
Filter C14 for color temperature
correction
Measurement Point
Display data of page 1
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
32 to 35
Specified Value
R ratio: 2C7C to 2D7C
B ratio: 5BD0 to 5CD0
Note1: This adjustment should be carried out upon completion of "Auto
White Balance & LV Standard Data Input".
Note2: After the power is turned on, this adjustment can be done only
once.
Note3: The data of page: 0, address: 10 must be "00".
Note4: Check that the data of page: 6, address: 02 is "00". If not, turn the
power of the unit OFF/ON.
Note5: Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
DIGITAL ZOOM (Menu display) ................................... OFF
4)
STEADY SHOT (Menu display) ..................................... OFF
Display data
DCR-IP210/IP210E/IP220/IP220E
Adjusting method:
Order Page Address Data
1
2
0
01
3
F
44
4
F
44
5
F
45
6
F
45
7
F
46
8
F
46
9
F
47
10
F
47
11
6
01
12
6
01
13
6
02
14
6
01
15
0
03
16
1
17
0
03
18
1
Note6: The adjustment data will be automatically input to page: F, address:
32 to 35.
Processing after Completing Adjustments:
Order Page Address Data
1
F
44
2
F
45
3
F
46
4
F
47
5
6
01
6
0
03
7
0
01
8
6-31
Procedure
Place the C14 filter for color
temperature correction on the lens.
01
Set the data.
Write down the data.
2C
Set the data, and press PAUSE
button.
Write down the data.
FC
Set the data, and press PAUSE
button.
Write down the data.
5C
Set the data, and press PAUSE
button.
Write down the data.
50
Set the data, and press PAUSE
button.
83
Set the data, and press PAUSE
button.
81
Set the data, and press PAUSE
button.
Check that the data changes to
"01". (Note6)
3F
Set the data, and press PAUSE
button.
04
Set the data.
Check that the display data
(Note5) satisfies the R ratio
specified value.
05
Set the data.
Check that the display data
(Note5) satisfies the B ratio
specified value.
Procedure
Set the data that is written down
at step 3, and press PAUE button.
Set the data that is written down
at step 5, and press PAUE button.
Set the data that is written down
at step 7, and press PAUE button.
Set the data that is written down
at step 9, and press PAUE button.
00
Set the data, and press PAUSE
button.
00
Set the data.
00
Set the data.
Remove the C14 filter.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcr-ip210eDcr-ip220Dcr-ip220e

Table of Contents