Servo And Rf System Adjustment; Cap Fg Duty Adjustment (Vc-253 Board); Pll F & Lpf F Adjustment (Vc-253 Board) - Sony DCR-PC110 Service Manual

Digital video camera recorder
Hide thumbs Also See for DCR-PC110:
Table of Contents

Advertisement

3-3.

SERVO AND RF SYSTEM ADJUSTMENT

Before perform the servo and RF system adjustments, check that
the specified value of "54MHz/66MHz Origin Oscillation
Adjustment" of "CAMERA SYSTEM ADJUSTMENT" is satisfied.
Note: The lens block (CD-285 board) must be connected when performing
the adjustments.
Adjusting Procedure:
1.
Cap FG duty adjustment
2.
PLL f
& LPF f
adjustment
0
0
3.
Switching position adjustment
4.
AGC center level
5.
APC & AEQ adjustment
6.
PLL f
& LPF f
final adjustment
0
0

1. Cap FG Duty Adjustment (VC-253 Board)

Set the Cap FG signal duty cycle to 50% to establish an appropriate
capstan servo. If deviated, the uneven rotation of capstan and noise
can occur.
Measurement Point
Display data of page: 3, address: 03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
16
Specified Value
00
Adjusting method:
Order Page Address Data
1
2
0
01
01
3
3
01
1B
4
3
02
5
3
03
6
0
01
00
Note: If the data is "01", adjustment has errors or the mechanism deck is
defective.
Procedure
Close the cassette compartment
without inserting a cassette.
Set the data.
Set the data, and press PAUSE
button.
Check that the data changes in
the following order.
"1B" → "2B" → "00"
Check that the data is "00".
(Note)
Set the data.
2. PLL f
& LPF f
Adjustment (VC-253 Board)
0
0
Mode
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Adjusting method:
Order Page Address Data
1
0
01
2
3
01
3
3
02
4
3
03
5
0
01
Note: If bit2, bit3 or bit6 of the data is "1", there are errors.
For the error contents, see the following table. (For the bit values,
refer to "5-4. SERVICE MODE", "4-3. 3. Bit value discrimination".)
Bit value of page: 3,
address: 03 data
bit 6 = 1
bit 3 = 1
bit 2 = 1
5-43
VTR stop
Display data of page: 3, address: 03
Adjustment remote commander
C
1F, 20, 22, 29
Bit2, bit3 and bit6 are "0"
Procedure
01
Set the data.
30
Set the data, and press PAUSE
button.
Check that the data changes to
"00".
Check that bit2, bit3 and bit6 are
"0". (Note)
00
Set the data.
Error contents
LPF f
is defective
0
PLL f
final adjustment is defective
0
PLL f
final adjustment time-out
0