Flange Back Adjustment (2); Flange Back Check - Sony DCR-IP210 Adjustment

Hide thumbs Also See for DCR-IP210:
Table of Contents

Advertisement

8-2. Flange Back Adjustment (2)

Perform this adjustment after performing "Flange Back Adjustment
(1)".
Subject
Subject more than 500m away
(Subjects with clear contrast such as
buildings, etc.)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
11, 48 to 58
Note1: Perform this adjustment under the condition that the zoom switch
(RV4001 of the control switch block (SS-2980)) is surely
connected.
Note2: Make the lens horizontal and perform this adjustment.
Note3: The data of page: 0, address: 10 must be "00".
Note4: Check that the data of page: 6, address: 02 is "00". If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
COLOR SLOW SHUTTER ............................................. OFF
Preparations:
1)
Set the zoom lens to the TELE end and expose a subject that is
more than 500m away (subject with clear contrast such as
building, etc.). (Nearby subjects less than 500m away should
not be in the screen.)
Adjusting method:
Order Page Address Data
1
0
01
01
2
6
01
13
3
4
6
01
29
5
6
02
Note5: Don't touch the zoom switch, If you touch the zoom switch, the
zoom center adjustment data will be rewritten in the value that
isn't correct.
Note6: The adjustment data will be automatically input to page: F, address
11, 48 to 58.
Processing after Completing Adjustments:
Order Page Address Data
1
6
01
00
2
6
01
25
3
6
01
00
4
0
01
00
5
Procedure
Set the data.
Set the data, and press PAUSE
button. (Note5)
Place a ND filter on the lens so
that the optimum image is
obtain.
Set the data, and press PAUSE
button.
Check that the data changes to
"01". (Note6)
Procedure
Set the data, and press PAUSE
button.
Set the data, and press PAUSE
button.
Set the data, and press PAUSE
button.
Set the data.
Perform "Flange Back Check"
DCR-IP210/IP210E/IP220/IP220E

9. Flange Back Check

Subject
Measurement Point
Measuring Instrument
Specified Value
Note1: The data of page: 0, address: 10 must be "00".
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT (Menu display) ........................................ OFF
Note2: When the auto focus is ON, the lens can be checked if it is focused
or not by observing the data on the page 1 of the adjustment remote
commander.
1) Select page: 0, address: 03, and set data: 0F.
2) Page 1 shows the state of the focus.
1 : 00 : XX
Checking method:
1)
Select page: 6, address: 40, and set data: 01.
2)
Select page: 6, address: 41, and set data: 01.
3)
Place the Siemens star 2.0m from the front of the lens.
4)
To open the IRIS, decrease the luminous intensity to the
Siemens star up to a point before noise appear on the image.
5)
Shoot the Siemens star with the zoom TELE end.
6)
Turn on the auto focus.
7)
Check that the lens is focused (Note2).
8)
Select page: 6, address: 21, and set data: 10.
9)
Shoot the Siemens star with the zoom WIDE end.
10) Observe the TV monitor and check that the lens is focused.
Processing after Completing Adjustments:
1)
Select page: 6, address: 21, and set data: 00.
2)
Select page: 6, address: 40, and set data: 00.
3)
Select page: 6, address: 41, and set data: 00.
4)
Select page: 0, address: 03, and set data: 00.
6-27
Siemens star
(2.0m from the front of the lens)
(Luminance : approx. 200 lux)
Check operation on TV monitor
Focused at the TELE end and WIDE
end.
Odd: Focused