2. Bright Adjustment (DI-087 board)

Set the D range of the RGB decoder used to drive the LCD to the
specified value. If deviated, the LCD screen will become blackish
or saturated (whitish).
Note: Do either of the automatic adjustment or the manual adjustment.
2-1.

Automatic Adjustment

Mode
Camera
Subject
Arbitrary
Adjustment Page
C
Adjustment Address
7E
Note: The data of page: 0, address: 10 must be "00".
Adjusting method:
Order Page Address Data
1
0
01
01
2
3
00
0D
3
3
01
4
3
00
00
5
0
01
00
Procedure
Set the data.
Set the data, and press PAUSE
button.
Check that the data is "00".
Set the data, and press PAUSE
button.
Set the data.
DCR-IP210/IP210E/IP220/IP220E
2-2.

Manual Adjustment

Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note: The data of page: 0, address: 10 must be "00".
Adjusting method:
Order Page Address Data
1
0
01
2
C
7E
3
C
7E
4
0
01
A
Pedestal
6-39
Camera
Arbitrary
Pin ws (VG) of IC2201
Oscilloscope
C
7E
A = 7.6 ± 0.1V
Procedure
01
Set the data.
Change the data and set the
voltage (A) between the reversed
waveform pedestal and non-
reversed waveform pedestal to
the specified value.
Press PAUSE button.
00
Set the data.
Pedestal
2H
Fig. 6-1-18.