Electrical Connection - Falcon 1092 Continental User's Manual & Installation Instructions

Dual fuel
Table of Contents

Advertisement

Check the appliance is electrically safe and gas sound when you have finished.
Pressure testing
The gas pressure can be measured at the pressure test point
on the gas connection block.
Connect the pressure gauge. Turn on and light one of the
hotplate burners.
Turn on the control knob for the burner with the pressure
gauge fitted to let gas through.
See the data badge for test pressures.
Turn off the burners. Make sure that you reassemble the
burner top in the correct way on the burner body.

Electrical connection

This appliance must be installed by a suitably qualified
electrician to comply with the relevant electrical regulations,
and also the local electricity supply company requirements.
Warning: the appliance must be earthed.
n
n
Note: The cooker must be connected to the correct electrical
supply as stated on the voltage label on the cooker, through
a suitable cooker control unit incorporating a double-pole
switch, having a contact separation of at least 3 mm in all
poles.
The cooker must not be connected to an ordinary
n
n
domestic power point.
Access to the mains terminal is gained by removing the
electrical terminal cover box on the back panel. Connect
the mains cable to the correct terminals for your electrical
supply type (Fig. 7.13 and Fig. 7.14). Check that the links are
correctly fitted and that the terminal screws are tight.
Secure the mains cable using the cable clamp.
INSTALLATION
Current Operated Earth Leakage Breakers
The combined use of your cooker and other domestic
appliances may cause nuisance tripping, so we recommend
that the cooker is protected on an individual RCD (Residual
Current Device) or RCBO (Residual Current Breaker with
IF IN DOUBT, PLEASE CONSULT A SUITABLY QUALIFIED
L
N
10 mm² max
230 Vac 50 Hz
L1
N
L3
L2
6 mm² max
3N ac
230/400 V 50 Hz
23
Overload).
ELECTRICIAN.
6 mm² max
10 mm² max
Fig. 7.13
Fig. 7.14
6 mm² max

Advertisement