Installation; Dear Installer; Safety Requirements And Regulations; Provision Of Ventilation - Falcon 1092 Continental User's Manual & Installation Instructions

Dual fuel
Table of Contents

Advertisement

Check the appliance is electrically safe and gas sound when you have finished.
7.

Installation

Dear installer

Before you start your installation, please complete the details
below, so that, if your customer has a problem relating to
your installation, they will be able to contact you easily.
Installer's Name
Installer's Company
ArtNo.050-0011 - Installer information table
Installer's Telephone Number
Appliance Serial Number
Safety requirements and
regulations
This cooker must be installed in accordance with
n
n
the relevant instructions in this booklet, with the
relevant national and local regulations, and with
the local gas and electricity supply companies'
requirements.
If the appliance is to be installed in Switzerland,
n
n
the following regulations and directives should be
observed:
• SVGW - Gas principles G1: Gas installation.
• EKAS - Form. 1942: Liquid gas directive, Part 2.
• Cantonal instances regulations (e.g. fire safety
regulators).
This cooker is a Class 2 Subclass 1 appliance.
n
n
Before installation, make sure that the cooker is
n
n
suitable for your gas type and supply voltage. See
the data badge.
The appliance must be installed in accordance with
n
n
the regulations in force and only in a well ventilated
space.
Read the instructions before installing or using this
n
n
appliance.
INSTALLATION
In your own interest and that of safety, it is law
n
n
that all gas appliances be installed by competent
persons. Failure to install the appliance correctly
could invalidate any warranty or liability claims and
lead to prosecution.
This appliance can be converted for use on another
n
n
gas.

Provision of ventilation

This appliance is not connected to a combustion products
evacuation device. Particular attention shall be given to the
relevant requirements regarding ventilation.
All rooms require a window that can be opened, or
equivalent, while some rooms require a permanent vent in
addition to the window.
Location of cooker
The cooker may be installed in a kitchen/kitchen diner but
NOT in a room containing a bath or shower.
This appliance is designed for domestic cooking only. Use for
any other purpose could invalidate any warranty or liability
claim.
Note: An appliance for use on LPG must not be installed
in a room or internal space below ground level, e.g. in a
basement.

Conversion

A conversion kit for another gas is available for the cooker.
If the appliance is to be converted to another gas we
recommend that this is carried out before installation.
After converting the appliance, please attach the Gas
Conversion sticker over the appropriate area of the data
badge – this will identify the gas type for which the appliance
is now set.
18

Advertisement

Table of Contents
loading

Table of Contents