Download Print this page

Section 1 - Installation - Falcon E3478 Installation And Servicing Instruction

Steaming oven

Advertisement

SECTION 1 - INSTALLATION

UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE
MANUFACTURER ARE NOT TO BE ADJUSTED BY THE INSTALLER.
1.1 MODEL NUMBERS, NETT WEIGHTs
and DIMENSIONS
Width
Model
(mm)
E3478
600
Steaming Oven
1.2 SITING
The unit MUST be installed upon a FIRM, LEVEL floor in a well- lit position. It requires to be secured to this surface.
The oven can be positioned to within 150mm of a combustible wall.
WARNING:
ALWAYS TAKE CARE WHEN MOVING THE APPLIANCE AS IT IS HEAVY.
ALWAYS USE SAFETY GLOVES AND ENCLOSED FOOTWEAR.
DO NOT PULL THE APPLIANCE BY THE HANDLE.
1.3 ELECTRICITY SUPPLY
The unit is designed to be connected to an AC supply only, i.e., single phase or 3 phase 4 wire. The cable entry is
located at rear of appliance (25mm conduit).
The supply must be installed using a suitable isolating switch with a minimum contact separation of 3mm in all
poles. All wiring must be executed in accordance with regulations listed on the cover of this document.
Ensure that the mains power cable is routed free from the appliance to avoid damage.
We recommend supplementary electrical protection with the use of a residual current device (RCD). Periodical
testing, repair and fixing wiring connection should only be undertaken by a skilled and competent electrician.
This appliance is also provided with a terminal for connection of an external equipotential
conductor. This terminal is in effective electrical contact with all fixed exposed metal parts
of the appliance, and shall allow the connection of a conductor having a normal cross-
sectional area of up to 10mm². It is located on the rear panel and is identified by the
following symbol and must only be used for bonding purposes.
1.4 ELECTRICAL RATING
The rating is as stated below.
Model
E3478 Steaming oven
Depth
Height
Weight
(mm)
(mm)
(kg)
840
1625
92
L1
L2
L3
12.25A
12.25A
12.25A
Figure 1

Advertisement

loading