Figure 2-1. Field Communicator Menu Tree for the Rosemount 8600D
1. Process
Variables
2. Diagnostics
and Service
3. Basic Setup
1. Device
Setup
2. PV
3. AO
4. LRV
5. URV
4. Detailed
Setup
5. Review
Rosemount 8600 Vortex Flow Meter
1. PV
1. Volumetric Flow
2. PV % Range
2. Mass Flow
3. Analog Output
3. Velocity Flow
4. View Other
4. Totalizer
Variables
5. Pulse Frequency
6. Vortex Frequency
7. Electronics Temp
8. Calc Proc Density
9. Process Temp
- CJ Temperature
1. View Status
1. CJ Temp
2. Config Status
2. CJ Temp Units
3. Density Test Calc
4. Min/Max Temps
5. Self Test
6. Reset Xmtr
1. Test/Status
2. Loop Test
3. Pulse Output Test
1. PV
4. Flow Simulation
2. Shedding Frequency
5. D/A Trim
3. Configure Flow Simulation
6. Scaled D/A Trim
4. Enable Normal Flow
7. Shed Freq at URV
5. Mode
1. Tag
1. Transmitter Mode
2. Process Config
2. Process Fluid
3. Reference K Factor
3. Fixed Process Temp
4. Flange Type
4. Density / Dens Ratio
5. Mating Pipe ID
6. Variable Mapping
1. PV is
7. PV Unit
2. SV is
8. Range Values
3. TV is
9. PV Damping
4. QV is
- Auto Adjust Filter
1. URV
2. LRV
3. PV Min Span
4. USL
5. LSL
1.Characterize Meter
2. Configure Outputs
1.Anlg Output
3. Signal Processing
4. Device Information
2. Pulse Output
3.HART Output
4. Local Display
1. Optimize Flow Range
2. Manual Filter Adjust
3. Filter Restore
4. Damping
5. LFC Response
1. Manufacturer
2. Tag
3. Descriptor
4. Message
5. Date
6. Write Protect
7. Transmitter Options
8. Revision Numbers
1. Volume Flow
2. Units
3. Special Units
1. Proc Temp
2. Proc Temp
Units
3. T/C Failure
Mode
1. Min Electr Temp
1. Proc
2. Max Electr Temp
Density
2. Density
Units
1. Density Ratio
2. Fixed Process
Density
1. K Factor
2. Mating Pipe ID
3. Flange Type
4. Wetted Material
5. Meter Body #
6. Installation Effects
1. Range Values
2. Loop Test
3. Alarm Jumper
4. D/A Trim
5. Alarm Level Select
6. Alarm/Sat Levels
7. Scaled D/A Trim
8. Recall Factory Trim
1. PV
2. LFC
1. Pulse Output
3. Sig/Tr
2. Pulse Output Test
4. Auto Adjust
Filter
1. Poll Address
2. # of Req Preams
1. PV
3. Num Resp Preams
2. Sig/Tr
4. Burst Mode
3. Low Flow Cutoff
5. Burst Option
4. Low Pass Filter
6. Burst Xmtr Vars
5. Trigger Level
1. Universal Rev
1. PV Damping
2. Transmitter Rev
2. Flow Damping
3. Software Rev
3. Temperature Damping
4. Hardware Rev
5. Final Assembly #
6. Device ID
7. Board Serial #
Configuration
00809-0100-4860, Rev BF
1. Base Volume Unit
2. Base Time Unit
3. User Defined Unit
4. Conversion Number
1. Mass Flow
2. Mass Flow Unit
1. Vel. Flow
2. Vel. Flow Unit
3. Velocity Meas Base
1. Total
2. Start
3. Stop
4. Reset
5. Totalizer Config
1. Electr Temp
2. Elec Temp Units
1. Density Ratio
2. Calc Density Ratio
1. Operating Conditions
2. Base Conditions
3. Exit
1. Reference K Factor
2. Compensated K Factor
1. URV
2. LRV
3. PV Min Span
4. USL
5. LSL
1. High Alarm
2. High Saturation
3. Low Saturation
4. Low Alarm
1. Off
2. Direct (Shedding)
3. Scaled Volume
4. Scaled Velocity
5. Scaled Mass
1.Xmtr Var, Slot 1
2.Xmtr Var, Slot 2
3.Xmtr Var, Slot 3
4.Xmtr Var, Slot 4
19